Cardiac cooling increases Emax without affecting relation between O2 consumption and systolic pressure-volume area in dog left ventricle.

نویسندگان

  • H Suga
  • Y Goto
  • Y Igarashi
  • Y Yasumura
  • T Nozawa
  • S Futaki
  • N Tanaka
چکیده

We studied the effects of cardiac cooling by 7 +/- 2 degrees C (SD) from 36 degrees C on both contractility index (Emax) and the relation between O2 consumption per beat (VO2) and systolic pressure-volume area (PVA) of the left ventricle in the excised cross-circulated dog heart preparation. PVA represents the total mechanical energy generated by a contraction. The VO2-PVA relation divides measured VO2 into unloaded VO2 and excess VO2. The slope of the VO2-PVA relation represents inversely the efficiency of the contractile machinery to convert chemical energy from the excess VO2 to total mechanical energy. Cooling is known to decrease myosin ATPase activity (Q10 of 2-3), which in turn is expected to increase the chemomechanical efficiency of cross bridges. Therefore, we expected an increase in the efficiency and hence a decreased slope of the VO2-PVA relation with cooling. The cooling increased Emax by 46 +/- 13% and the time to Emax by 45 +/- 27%. Pacing rate was constant or had to be slightly decreased to avoid arrhythmias with cooling. We found that neither the slope of the VO2-PVA relation nor unloaded VO2 significantly (p greater than 0.05) changed with the cooling. This result contradicts the expected increase in the efficiency with cooling. We conclude that cardiac cooling by 7 degrees C from 36 degrees C does not increase the efficiency of the contractile machinery in excised cross-circulated dog left ventricle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of cardiac cooling under surface-induced hypothermia on the cardiac function in the in situ heart.

It has been reported that in the excised cross-circulated dog heart model, cardiac cooling increases Emax (contractility index) and the external work (EW) of the left ventricle without affecting the systolic pressure volume area (PVA)-independent myocardial oxygen consumption (VO2). However, it remains unclear whether this cooling inotropism and oxygen-saving effect can also be demonstrated in ...

متن کامل

Increased oxygen cost of contractility in stunned myocardium of dog.

Recent studies have shown that myocardial oxygen consumption does not proportionally decrease with the deterioration of contractile function in stunned myocardium. To investigate this disproportion, we studied the end-systolic pressure-volume relation and the relation between oxygen consumption per beat (VO2) and systolic pressure-volume area (PVA, a measure of total mechanical energy) in stunn...

متن کامل

Effect of positive inotropic agents on the relation between oxygen consumption and systolic pressure volume area in canine left ventricle.

We analyzed the effect of positive inotropic agents on the relation between left ventricular oxygen consumption and the systolic pressure-volume area. Pressure-volume area is a measure of total mechanical energy for ventricular contraction, and is a specific area in the ventricular pressure-volume diagram circumscribed by the end-systolic and end-diastolic pressure-volume relation curves and th...

متن کامل

Effect of coronary hyperemia on Emax and oxygen consumption in blood-perfused rabbit hearts. Energetic consequences of Gregg's phenomenon.

To assess the relation between increases in contractile function and oxygen consumption (VO2) during increased coronary flow (Gregg's phenomenon), we measured the end-systolic pressure-volume relation and the relation between VO2 and left ventricular systolic pressure-volume area (PVA, a measure of total mechanical energy output) in blood-perfused, isovolumically contracting rabbit hearts durin...

متن کامل

Relation between maximum time-varying elastance pressure-volume areas and myocardial oxygen consumption in dogs.

To establish whether pressure-volume areas (PVAs) calculated using the maximum time-varying elastance (Emax) have a relation with myocardial oxygen consumption (MVO2) that improves on other indexes of myocardial oxygen demand, we studied nine dogs of either sex weighing 19-39 kg, which were instrumented with a micromanometer left ventricular (LV) catheter and a Wilton-Webster coronary sinus flo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 63 1  شماره 

صفحات  -

تاریخ انتشار 1988