Measurement of biocolloid collision efficiencies for granular activated carbon by use of a two-layer filtration model.
نویسندگان
چکیده
Point-of-use filters containing granular activated carbon (GAC) are an effective method for removing certain chemicals from water, but their ability to remove bacteria and viruses has been relatively untested. Collision efficiencies (alpha) were determined using clean-bed filtration theory for two bacteria (Raoutella terrigena 33257 and Escherichia coli 25922), a bacteriophage (MS2), and latex microspheres for four GAC samples. These GAC samples had particle size distributions that were bimodal, but only a single particle diameter can be used in the filtration equation. Therefore, consistent with previous reports, we used a particle diameter based on the smallest diameter of the particles (derived from the projected areas of 10% of the smallest particles). The bacterial collision efficiencies calculated using the filtration model were high (0.8 < or = alpha < or = 4.9), indicating that GAC was an effective capture material. Collision efficiencies greater than unity reflect an underestimation of the collision frequency, likely as a result of particle roughness and wide GAC size distributions. The collision efficiencies for microspheres (0.7 < or = alpha < or = 3.5) were similar to those obtained for bacteria, suggesting that the microspheres were a reasonable surrogate for the bacteria. The bacteriophage collision efficiencies ranged from > or = 0.2 to < or = 0.4. The predicted levels of removal for 1-cm-thick carbon beds ranged from 0.8 to 3 log for the bacteria and from 0.3 to 1.0 log for the phage. These tests demonstrated that GAC can be an effective material for removal of bacteria and phage and that GAC particle size is a more important factor than relative stickiness for effective particle removal.
منابع مشابه
Experimental and Theoretical Study on the CH4 Adsorption by Granular and Microporous Activated Carbon
Adsorbed natural gas (ANG) by Granular Activated Carbon (GAC) has been widely investigated as an alternative to CNG and LNG technologies for storage and transportation of natural gas. In the present work, a theoretical and experimental study was conducted to accurately determine the amount of adsorption of CH4 by GAC. To carry out the experiments, the volumetric method was used up to 4 MPa at c...
متن کاملComparative potential of black tea leaves waste to granular activated carbon in adsorption of endocrine disrupting compounds from aqueous solution
The adsorption properties and mechanics of selected endocrine disrupting compounds; 17 β-estradiol, 17 α – ethinylestradiol and bisphenol A on locally available black tea leaves waste and granular activated carbon were investigated. The results obtained indicated that the kinetics of adsorption were pH, adsorbent dose, contact time and temperature dependent with equilibrium being reached at 20 ...
متن کاملRemoval of copper (II) from aqueous solutions by adsorption onto granular activated carbon in the presence of competitor ions
In this work, the removal of copper from an aqueous solution by granular activated carbon (GAC) in the presence of competitor ions was studied. A batch adsorption was carried out and different parameters such as pH, contact time, initial copper concentration and competitor ions concentration were changed to determine the optimum conditions for adsorption. The optimum pH required for maximum ads...
متن کاملStatistical physics modeling of equilibrium adsorption of cadmium ions onto activated carbon, chitosan and chitosan/activated carbon composite
The adsorption ability of activated carbon, chitosan, and chitosan/activated carbon composite for cadmium separation from aqueous solution was analyzed via statistical physical modeling. The equilibrium data were analyzed by Langmuir, Hill, double layer model, and the multi-layer model with saturation isotherm models. Results showed that the multi-layer model with saturation could well describe...
متن کاملRemoval of Coliform, Suspended Solids, UV254 and Colour Using Zeolite and Activated Carbon in Riverbank Filtration System
River bank filtratio filtration (RBF) is one of the novel water abstraction alternatives to tackle poor water quality problem in Malaysia. This study was conducted to investigate the potential use of zeolite and activated carbon as filter media in the laboratory RBF system. Characteristics of the materials were first determined using the surface analyzer and X-ray fluorescence method. Filter co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied and environmental microbiology
دوره 72 8 شماره
صفحات -
تاریخ انتشار 2006