We modified a p24 antigen enzyme-linked immunosorbent assay as a method for diagnosis and monitoring of human immunodeficiency virus type 1 (HIV-1) subtype E infection. This modified assay is based on the use of preheated immune complex dissociation combined with a booster step using a regular Vironostika HIV-1 p24 antigen assay (bioMerieux) to decrease the lower limit of p24 antigen detection from 10 pg/ml (lower limit achievable when using a regular p24 antigen assay) to 0.5 pg/ml (100 virions/ml) by the new method. The correlation between the values obtained by the HIV-1 RNA (Amplicor HIV-1 Monitor) assay and the p24 antigen assay modified with a booster step antigen assay in 160 frozen plasma samples with known viral load and 80 blind fresh plasma samples by Spearman rank were 0.671 (R(2) = 0.450; P < 0.01) and 0.782 (R(2) = 0.612; P < 0.01). During antiretroviral treatment, the change of p24 antigen level at >/=0.5 log correlated well with the level of HIV-1 in plasma. In order to improve the early diagnosis of HIV-1 infection in 121 infants born to HIV-1-infected mothers, a heat-denatured plasma p24 antigen assay modified with a booster step was compared with DNA-PCR and HIV RNA (nucleic acid sequence-based amplification) assays. The sensitivity of the antigen test modified with a booster step was similar to that of the HIV-1 RNA (NASBA QL) assay and better than that of the DNA-PCR assay (100 versus 61.90%) for subjects 1 to 2 months old. The overall results from this study might renew interest in p24 antigen detection as an easily affordable alternative method for diagnosis of HIV-1 infection and monitoring of disease progression in developing countries.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

راه‌اندازی و به‌کارگیری روش الیزا به‌منظور تشخیص حضور آنتی‌ژن p24 در خون افراد آلوده به HIV

Introduction: Human immunodeficiency virus is the etiologic agent of immune system deficiency and the infected patients are susceptible to opportunistic infections and AIDS. Transmission of infection during blood transfusion and diagnosis of infection in hospitals and public health settings have steadily been a worldwide concern. Different techniques are now available for the diagnosis of HIV i...

متن کامل

Prospective evaluation of amplification-boosted ELISA for heat-denatured p24 antigen for diagnosis and monitoring of pediatric human immunodeficiency virus type 1 infection.

The performance in pediatric human immunodeficiency virus type 1 (HIV-1) infection of a signal-amplification boosted ELISA for HIV-1 p24 antigen in plasma after heat-mediated immune complex dissociation was prospectively compared with polymerase chain reaction-based procedures. Diagnostic sensitivity and specificity of the p24 antigen test were 100% and 99.2%, respectively. Quantification revea...

متن کامل

Detection of p24 antigen with and without immune complex dissociation for longitudinal monitoring of human immunodeficiency virus type 1 infection.

Sequential specimens obtained from 87 multicenter AIDS cohort study participants were tested by three p24 antigen tests. They included a polyclonal enzyme immunoassay (EIA), a monoclonal EIA, and a monoclonal EIA after immune complex dissociation (ICD) of specimens. Subjects were grouped into two categories defined by real-time testing with the polyclonal EIA: 39 had become positive for p24 ant...

متن کامل

The Prevalence of Hepatitis B, Hepatitis C, and Human Immunodeficiency Virus Infections among β-thalassemia Major: A Multicenter Survey in Lorestan, West of Iran

Background: Although regular frequent blood transfusion improves overall survival of multi-transfused patients like &beta;-thalassemic ones, it carries a definite risk of infection with blood-borne viruses such as viral hepatitis. This study was done to determine seropositivity of hepatitis B virus (HBV), hepatitis C virus (HCV), and Human Immunedeficiency Virus (HIV) infections among &beta;-th...

متن کامل

Nanoparticle-Based biobarcode amplification assay (BCA) for sensitive and early detection of human immunodeficiency type 1 capsid (p24) antigen.

Nanotechnology-based techniques are being widely evaluated in medical testing and could provide a new generation of diagnostic assays due to their high degrees of sensitivity, high specificity, multiplexing capabilities, and ability to operate without enzymes. In this article, we have modified a nanoparticle-based biobarcode amplification (BCA) assay for early and sensitive detection of HIV-1 c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 41 3  شماره 

صفحات  -

تاریخ انتشار 2003