Early and midterm results of totally endoscopic coronary artery bypass grafting on the beating heart.
نویسندگان
چکیده
OBJECTIVE Despite the early introduction of totally endoscopic coronary artery bypass on the beating heart, only a limited number of cases have been performed. The limiting factor has been the concern about safety and graft patency of the anastomosis. This study describes our experience with totally endoscopic coronary artery bypass on the beating heart with robotic assistance and its early and midterm results. METHODS In 365 cases of robotic cardiac operations, 162 patients underwent robotic coronary artery bypass grafting on the beating heart, of whom 60 patients (46 male, 14 female) underwent totally endoscopic coronary artery bypass on the beating heart. The patients' mean age was 56.97 ± 9.7 years (33-77 years). Left internal thoracic artery to left anterior descending anastomosis was performed using the U-Clip device. RESULTS We completed 58 totally endoscopic coronary artery bypass procedures, in which 16 patients received hybrid procedures. Two patients had conversions to a minithoracotomy. The average left internal thoracic artery harvesting and anastomosis times were 31.3 ± 10.5 (18∼55) minutes and 11.3 ± 4.7 (5∼21) minutes, respectively. The mean operating room and operation times were 336.1 ± 58.5 (210∼580) minutes and 264.8 ± 65.6 (150∼420) minutes, respectively. The drainage was 164.9 ± 83.2 (70∼450) mL. Before discharge, 50 patients underwent angiography and 8 patients underwent computed tomography angiography, and the study showed that graft patency was 100%. Unexpectedly, the left internal thoracic artery graft developed a collateral branch in 2 patients. After discharge, all patients were followed up by computed tomography angiography. The average follow-up time was 12.67 ± 9.43 (1-40) months. One patient had gastric bleeding after surgery. CONCLUSIONS Totally endoscopic coronary artery bypass on the beating heart is a safe procedure in selected patients and produces excellent early and midterm patency of anastomosis.
منابع مشابه
Integrating coronary anastomotic connectors and robotics toward a totally endoscopic beating heart approach: review of 120 cases.
BACKGROUND Endoscopic coronary bypass has been a difficult procedure to perform. The recent introduction of the Intuitive EndoWrist stabilizer (Intuitive Surgical, Sunnyvale, CA) has facilitated this procedure robotically on the beating heart. The addition of anastomotic connectors allows a significant improvement in the execution of this technically demanding procedure. We report on our first ...
متن کاملUse of Carbon dioxide versus air blower in on-pump beating-heart coronary artery bypass surgery
Introduction: The use of carbon dioxide blower has been recognized as the standard of care in patients undergoing beating coronary artery bypass grafting (CABG) due to higher solubility and lower risk of embolization. On the other hand, the compressed air blower has gone out of use since air can be easily trapped and is less soluble which can cause coronary embolism. The prese...
متن کاملHistory and current status of robotic totally endoscopic coronary artery bypass.
Robotic totally endoscopic coronary artery bypass (TECAB) is a minimally invasive endoscopic surgical approach using the daVinci robotic telemanipulation system to perform coronary artery bypass grafting on the arrested or beating heart. It is a procedure that can be a useful alternative to the classic open procedure performed through sternotomy. After extensive modeling in cadavers, the first ...
متن کاملPii: S1569-9293(02)00008-7
Telemanipulators have been introduced into cardiac surgery recently expanding the scope of minimally invasive techniques and enabling endoscopic cardiac surgery. Our aim was to evaluate clinical results of totally endoscopic single vessel bypass grafting on the arrested as well as on the beating heart. Since 1999, 44 totally endoscopic single vessel arterial bypass grafting procedures were perf...
متن کاملFacilitated endoscopic beating heart coronary artery bypass grafting using a magnetic coupling device.
BACKGROUND Suturing of a coronary anastomosis in totally endoscopic coronary artery bypass grafting on the beating heart is technically demanding. The potential benefits of the endoscopic Magnetic Vascular Positioner device (Ventrica, Inc, Fremont, Calif) to facilitate construction of a coronary anastomosis in a closed chest environment were evaluated. METHODS Totally endoscopic coronary arte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of thoracic and cardiovascular surgery
دوره 142 4 شماره
صفحات -
تاریخ انتشار 2011