DMLC leaf-pair optimal control for mobile, deforming target.

نویسندگان

  • Lech Papiez
  • Dharanipathy Rangaraj
چکیده

Existing algorithms of dynamic control of independent pairs of leaves allow optimal DMLC delivery of IMRT to rigid targets translating parallel to leaf trajectories. However, in numerous cases of radiotherapy treatments simplifying assumptions of rigid-like motions of targets and surrounding tissues are clearly not satisfied. Therefore algorithms have to be developed that allow one to control MLC so that predetermined intensities are delivered to various points in targets that experience compression and expansion at the time of irradiation. Moreover, it is desirable for such algorithms to ensure that delivery of modulated intensity map will be done with minimal expense of monitor units. Derivation of the algorithm that optimizes the DMLC IMRT to mobile, deforming target is presented in this paper. [To illustrate the general algorithm two representative examples of DMLC IMRT delivery to deforming targets are presented in full detail.] Finally, similarities and differences between solutions for immobile targets, for moving, rigid targets and for moving, deforming targets are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capability of leaf interdigitation with different inverse planning strategies in Monaco: an investigation of representative tumour sites

PURPOSE The aim of this study was to experimentally assess the dosimetric impact of leaf interdigitation using different inverse treatment strategies for representative tumour sites and to identify the situations in which leaf interdigitation can benefit these tumour sites. MATERIAL AND METHODS Sixty previously treated patients (15 nasopharyngeal carcinoma (NPC), 15 multiple brain metastasis ...

متن کامل

Management of three-dimensional intrafraction motion through real-time DMLC tracking.

Tumor tracking using a dynamic multileaf collimator (DMLC) represents a promising approach for intrafraction motion management in thoracic and abdominal cancer radiotherapy. In this work, we develop, empirically demonstrate, and characterize a novel 3D tracking algorithm for real-time, conformal, intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT)-based radiation...

متن کامل

Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking system.

PURPOSE Dynamically compensating for target motion during radiotherapy will increase treatment accuracy. A laboratory system for real-time target tracking with a dynamic MLC has been developed. In this study, the geometric accuracy limits of this DMLC target tracking system were evaluated. METHODS AND MATERIALS A motion simulator was programmed to follow patient-derived tumor motion paths, pa...

متن کامل

Optimal Sequencing of Dynamic Multileaf Collimators

Dynamic multileaf collimator (DMLC)-intensity modulated radiation therapy (IMRT) is used to delivery intensity-modulated beams using an MLC, with the leaves in motion. DMLC-IMRT requires the conversion of a radiation fluence map into a leaf sequence file that controls the movement of the MLC while the beam is on. It is imperative that the fluence map delivered using the leaf sequence file be as...

متن کامل

Dosimetric characteristics of LinaTech DMLC H multi leaf collimator: Monte Carlo simulation and experimental study

This study evaluated the basic dosimetric characteristics of a Dynamic Multi Leaf Collimator (DMLC) using a diode detector and film measurements for Intensity Modulated Radiation Therapy Quality Assurance (IMRT QA). The EGSnrc Monte Carlo (MC) simulation system was used for the determination of MLC characteristics. Radiation transmission and abutting leaf leakage relevant to the LinaTech DMLC H...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 32 1  شماره 

صفحات  -

تاریخ انتشار 2005