Synchronizing the transcranial magnetic pulse with electroencephalographic recordings effectively reduces inter-trial variability of the pulse artefact

نویسندگان

  • Leo Tomasevic
  • Mitsuaki Takemi
  • Hartwig Roman Siebner
چکیده

BACKGROUND Electroencephalography (EEG) can capture the cortical response evoked by transcranial magnetic stimulation (TMS). The TMS pulse provokes a large artefact, which obscures the cortical response in the first milliseconds after TMS. Removing this artefact remains a challenge. METHODS We delivered monophasic and biphasic TMS to a melon as head phantom and to four healthy participants and recorded the pulse artefact at 5 kHz with a TMS-compatible EEG system. Pulse delivery was either synchronized or non-synchronized to the clock of the EEG recording system. The effects of synchronization were tested at 10 and 20 kHz using the head phantom. We also tested the effect of a soft sheet placed between the stimulation coil and recording electrodes in both human and melon. RESULTS & CONCLUSION Synchronizing TMS and data acquisition markedly reduced trial-to-trial variability of the pulse artefact in recordings from the phantom or from the scalp. Reduced trial-to-trial variability was also observed at high sampling frequencies. The use of a soft sheet reduced the variability in recordings on the head phantom, but not in human participants. Effective reduction of the trial-to-trial variability renders it possible to create an artefact template for off-line filtering. Template-based subtraction of the artefact from the EEG signals is a prerequisite to effectively recover the immediate physiological response in the stimulated cortex and inter-connected areas.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter-pulse Interval Affects the Size of Single-pulse TMS-induced Motor Evoked Potentials: a Reliability Study

Introduction: Measuring the size of motor evoked potentials (MEPs) induced by transcranial magnetic stimulation (TMS) is an investigational technique to show the level of corticospinal excitability however, some of the fundamental methodological aspects of TMS (such as the effects of inter-pulse intervals (IPI) on MEP size) are not fully understood, this issue raises concerns about the re...

متن کامل

Non Invasive Brain Stimulation by Transcranial Magnetic Stimulation (TMS): Principles and Applications

Magnetic brain stimulation used as a method of psychological interventions in the treatment of diseases. This method functions used in the treatment of clinical disorder such as speech and movement disorders caused by stroke, tinnitus, Parkinson's disease, nervous tics. Applications in the field of psychological therapy, it is possible to stimulate specific brain area involved in certain mental...

متن کامل

Real-time rejection of gradient and pulse related artefact (GRA and PRA) from electroencephalographic signals recorded during functional magnetic resonance imaging (fMRI)

Electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) are two imaging techniques used to study the dynamical activity of the human brain. Although complementary, i.e. EEG has a high temporal resolution while fMRI provides precise volumic information, the simultaneous use of both techniques introduces large artefacts in the EEG recordings. These artefacts are consequences...

متن کامل

Measures to Predict The Individual Variability of Corticospinal Responses Following Transcranial Direct Current Stimulation

Individual responses to transcranial direct current stimulation (tDCS) are varied and therefore potentially limit its application. There is evidence that this variability is related to the contributions of Indirect waves (I-waves) recruited in the cortex. The latency of motor-evoked potentials (MEPs) can be measured through transcranial magnetic stimulation (TMS), allowing an individual's respo...

متن کامل

rTMS-evoked potentials, 1 Brain responses evoked by high-frequency repetitive TMS: An ERP study

Background: Many recent studies have employed repetitive transcranial magnetic stimulation (rTMS) to study brain-behavior relationships. However, the pulse-to-pulse neural effects of rapid delivery of multiple TMS pulses are unknown largely because of TMS-evoked electrical artifacts limiting recording of brain activity. Objective: In this study, TMS-related artifacts were removed with independe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017