Pii: S0730-725x(01)00247-8
نویسندگان
چکیده
We have extended the utility of NMR as a technique to probe porous media structure over length scales of ;100–2000 mm by using the spin 1/2 noble gas Xe imbibed into the system’s pore space. Such length scales are much greater than can be probed with NMR diffusion studies of water-saturated porous media. We utilized Pulsed Gradient Spin Echo NMR measurements of the time-dependent diffusion coefficient, D(t), of the xenon gas filling the pore space to study further the measurements of both the pore surface-area-to-volume ratio, S/Vp, and the tortuosity (pore connectivity) of the medium. In uniform-size glass bead packs, we observed D(t) decreasing with increasing t, reaching an observed asymptote of ;0.62–0.65D0, that could be measured over diffusion distances extending over multiple bead diameters. Measurements of D(t)/D0 at differing gas pressures showed this tortuosity limit was not affected by changing the characteristic diffusion length of the spins during the diffusion encoding gradient pulse. This was not the case at the short time limit, where D(t)/D0 was noticeably affected by the gas pressure in the sample. Increasing the gas pressure, and hence reducing D0 and the diffusion during the gradient pulse served to reduce the previously observed deviation of D(t)/D0 from the S/Vp relation. The Pade approximation is used to interpolate between the long and short time limits in D(t). While the short time D(t) points lay above the interpolation line in the case of small beads, due to diffusion during the gradient pulse on the order of the pore size, it was also noted that the experimental D(t) data fell below the Pade line in the case of large beads, most likely due to finite size effects. © 2001 Elsevier Science Inc. All rights reserved.
منابع مشابه
Pii: S0730-725x(01)00436-2
Functional MRI (fMRI) studies designed for simultaneously measuring Blood Oxygenation Level Dependent (BOLD) and Cerebral Blood Flow (CBF) signal often employ the standard Flow Alternating Inversion Recovery (FAIR) technique. However, some sensitivity is lost in the BOLD data due to inherent T1 relaxation. We sought to minimize the preceding problem by employing a modified UN-inverted FAIR (UNF...
متن کاملPii: S0730-725x(01)00428-3
The subtle signal changes in functional magnetic resonance imaging (fMRI) can be easily overwhelmed by noise of various origins. Spikes in the collected fMRI raw data often arise from high-duty usage of the scanner hardware and can introduce significant noise in the image and thereby in the image time series. Consequently, the spikes will corrupt the functional data and degrade the result of fu...
متن کاملPii: S0730-725x(01)00410-6
The architecture of baked breads made of fresh dough and frozen dough was depicted by magnetic resonance imaging (MRI). Pieces of bread (16 mm cubic cakes) were soaked in organic solvents containing various concentrations of heavy metals (Cu, Co and Fe) and images of the grain structure of the breads were obtained. Of the organic solvents tested, acetone was preferable because of its single pea...
متن کاملPii: S0730-725x(01)00404-0
In this work, computational methods were utilized to optimize the field produced by the transverse electromagnetic (TEM) resonator in the presence of the human head at 8 Tesla. Optimization was achieved through the use of the classical finite difference time domain (FDTD) method and a TEM resonator loaded with an anatomically detailed human head model with a resolution of 2 mm 2 mm 2 mm. The he...
متن کاملPii: S0730-725x(01)00393-9
Electric Current Density Imaging (CDI) is a new modality of magnetic resonance imaging that enables electric current distribution imaging in conductive samples containing water. So far, two CDI techniques have been in use: DC-CDI operating at zero frequency and RF-CDI operating at the RF Larmor frequency. In this paper we present a new CDI technique, which extends the CDI frequency range to alt...
متن کامل