Day to day treatment variations of accelerated partial breast brachytherapy using a multi-lumen balloon

نویسندگان

  • Hsiang-Chi Kuo
  • Keyur J. Mehta
  • Linda Hong
  • Ravindra Yaparpalvi
  • Leslie L. Montgomery
  • William Bodner
  • Wolfgang A. Tomé
  • Shalom Kalnicki
چکیده

PURPOSE To evaluate the variations of multi-lumen balloon (MLB)-based brachytherapy from simulation day to treatment day and their dosimetric impacts during accelerated partial breast irradiation (APBI). MATERIAL AND METHODS A total of 42 CT images scanned from seven patients were evaluated with regards to daily variation due to of: 1) internal uncertainty: size and shape of balloon, seroma volume; 2) geometrical uncertainty-random: length of each catheter was measured for each fraction (total 70); 3) geometrical uncertainty-systematic: virtual systematic errors were tested by offsetting dwell positions. The original plans (as group A) had a mean value of 96.8% on V95 of the PTV_Eval. Plans were rerun (as group B) such that the mean value of the V95 was relaxed to 90.4%. By applying the reference plan to each daily CT image, variations of target coverage under different sources of error were evaluated. RESULTS Shape and size of the balloon had means of < 1 mm decreased in diameter and < 0.4 cm(3) decreased in volume; the mean seroma volume increased by 0.2 cm(3). This internal variation has a mean of < 1% difference for both V90 and V95. The geometrical uncertainty made a mean deviation of 2.7 mm per root of sum of square. It caused the degradations of V90 and V95 by mean values of 1.0% and 1.2%, respectively. A systematic error of 3 mm and 4 mm would degrade both of V90 and V95 by 4% and 6%, respectively. The degradations on target coverage of the plans in group A were statistically the same as those in group B. CONCLUSIONS Overall, APBI treatments with MLB based brachytherapy are precise from day to day. However, minor variation due to daily treatment uncertainties can still degrade tumor bed coverage to an unacceptable coverage when V95 of the original plan is close to 90%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of Skin Dose Delivered with MammoSite and Multicatheter Breast Brachytherapy

Background: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients treated with breast brachytherapy.Objective: To investigate the percentage of the dose received by critical organ (skin), thermoluminescence detec...

متن کامل

Dosimetric Improvements in Balloon Based Brachytherapy Using the Contura® Multi-Lumen Balloon (MLB) Catheter to Deliver Accelerated Partial Breast Irradiation

PURPOSE Preliminary dosimetric findings in patients managed with the Contura® Multi-Lumen Balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) on a multi-institutional phase IV registry trial were reviewed. MATERIAL AND METHODS CT-based 3D planning with dose optimization was performed for all patients. For the study, new ideal dosimetric goals w...

متن کامل

Consideration of accurate dose distribution for Contura balloon catheter in breast brachytherapy with MCNP5 simulation

Introduction: Contura is a balloon applicator that used to deliver intra cavity radiation for Partial Breast Irradiation (PBI) treatments. Contura with 4 peripheral lumens surrounding the central, for loading HDR sources from an after loader system can provide an asymmetric dose distribution and gives a more flexible shape of dose than earlier balloon applicators such as Mammo...

متن کامل

WBRT vs. APBI: an interim report of patient satisfaction and outcomes

PURPOSE To determine differences in patient's reported quality of life and self-reported breast cosmesis between whole breast radiation therapy (WBRT) and accelerated partial breast irradiation (APBI) via single and multi-lumen high-dose-rate (HDR) brachytherapy for women with early stage breast cancer. MATERIAL AND METHODS Patient information was retrospectively reviewed and survey data were...

متن کامل

Four-year results using balloon-based brachytherapy to deliver accelerated partial breast irradiation with a 2-day dose fractionation schedule.

PURPOSE We present 4-year results from a Phase I/II trial using balloon-based brachytherapy to deliver accelerated partial breast irradiation in 2 days. MATERIALS/METHODS Forty-five patients received breast-conserving surgery followed by adjuvant radiation therapy using a balloon-based brachytherapy applicator delivering 2800 cGy in four fractions over 2 days. Outcomes analyzed include toxici...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2014