Design of a decoupled MRI-compatible force sensor using fiber bragg grating sensors for robot-assisted prostate interventions

نویسندگان

  • Reza Monfaredi
  • Reza Seifabadi
  • Gabor Fichtinger
  • Iulian Iordachita
چکیده

During prostate needle insertion, the gland rotates and displaces resulting in needle placement inaccuracy. To compensate for this error, we proposed master-slave needle steering under real-time MRI in a previous study. For MRIcompatibility and accurate motion control, the master (and the slave) robot uses piezo actuators. These actuators however, are non-backdrivable. To cope with this issue, force sensor is required. Force sensor is also required at the slave side to reflect the insertion force to clinician’s hand through the master robot. Currently, there is no MRIcompatible force sensor commercially available. In order to generate a combination of linear and rotary motions for needle steering, this study is seeking to develop a MRI-compatible 2 Degrees of Freedom (DOF) force/torque sensor. Fiber Brag Grating (FBG) strain measuring sensors which are proven to be MRI-compatible are used. The active element is made of phosphor-bronze and other parts are made of brass. The force and torque measurements are designed to be entirely decoupled. The sensor measures -20 to 20 N axial force with 0.1 N resolution, and -200 to 200 Nmm axial torque with 1 Nmm resolution. Analytical and Finite Element (FE) analyses are performed to ensure the strains are within the measurable range of the FBG sensors. The sensor is designed to be compact (diameter =15 mm, height =20 mm) and easy to handle and install. The proposed sensor is fabricated and calibrated using a commercial force/torque sensor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MRI-compatible Haptics: Strain sensing for real-time estimation of three dimensional needle deflection in MRI environments

Conventional closed-bore MRI scanners preclude direct “hands-on” device manipulation. There is a critical need for methods to quickly, accurately and easily manipulate instruments within closed MRI systems. Specifically, catheter, probe, and needle interventions can benefit from optical systems which measure tool positions and forces in real-time. During such procedures, it is useful to track a...

متن کامل

High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance...

متن کامل

Active Needle Steering System for Percutaneous Prostate Intervention in High-field MRI

This paper presents the design of a magnetic resonance imaging (MRI) compatible needle steering system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. Our guiding vision is to design a modular needle driver that can be coupled to a generic gross positioning stage to enhance MRI-guided prostate surgery accuracy and decrease operational time. After reviewing pertaining ...

متن کامل

XWH - 09 - 1 - 0191 TITLE : Development of an MRI - Guided Intra - Prostatic Needle Placement System

This paper presents the first prototype of a magnetic resonance imaging (MRI) compatible piezoelectric actuated robot integrated with a high-resolution fiber optic sensor for prostate brachytherapy with real-time in situ needle steering capability in 3T MRI. The 6-degrees-of-freedom (DOF) robot consists of a modular 3-DOF needle driver with fiducial tracking frame and a 3-DOF actuated Cartesian...

متن کامل

MEMS Bragg grating force sensor.

We present modeling, design, fabrication and characterization of a new type of all-optical frequency modulated MEMS force sensor based on a mechanically amplified double clamped waveguide beam structure with integrated Bragg grating. The sensor is ideally suited for force measurements in harsh environments and for remote and distributed sensing and has a measured sensitivity of -14 nm/N, which ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013