A novel method for the rapid modification of fullerene for subsequent enzyme attachment to create a potentiometric biosensor is presented. Urease was immobilized onto the modified fullerene nanomaterial. The modified fullerene-immobilized urease (C60-urease) bioconjugate has been confirmed to catalyze the hydrolysis of urea in solution. The biomaterial was then deposited on a screen-printed electrode containing a non-plasticized poly(n-butyl acrylate) (PnBA) membrane entrapped with a hydrogen ionophore. This pH-selective membrane is intended to function as a potentiometric urea biosensor with the deposition of C60-urease on the PnBA membrane. Various parameters for fullerene modification and urease immobilization were investigated. The optimal pH and concentration of the phosphate buffer for the urea biosensor were 7.0 and 0.5 mM, respectively. The linear response range of the biosensor was from 2.31 × 10-3 M to 8.28 × 10-5 M. The biosensor's sensitivity was 59.67 ± 0.91 mV/decade, which is close to the theoretical value. Common cations such as Na+, K+, Ca2+, Mg2+ and NH4+ showed no obvious interference with the urea biosensor's response. The use of a fullerene-urease bio-conjugate and an acrylic membrane with good adhesion prevented the leaching of urease enzyme and thus increased the stability of the urea biosensor for up to 140 days.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carbon Nanotubes-Based Potentiometric Bio-Sensors for Determination of Urea

The possibility of using disposable plastic-carbon potentiometric sensors as enzyme biosensors was examined. Urease enzyme was immobilized on poly(vinyl chloride) based Hor NH4-selective membranes using cellulose acetate. This approach has resulted in a potentiometric response on changing the pH of the solution or NH4 ion content due to an enzymatic reaction that occurs between urease and urea....

متن کامل

Development of Potentiometric Urea Biosensor For Clinical Purposes

This review summarizes the studies carried on the development of potentiometric urea biosensor in laboratory using urease from Cajanus cajan (local Arhar). The enzyme used was free without any immobilisation over matrix. The electrode used egg membrane or cellophane paper making ionic diffusion possible across the two solutions. Underlying the importance of this study is the fact that urea is t...

متن کامل

Development of a monoclonal antibody based potentiometric biosensor for terbuthylazine detection

In the present paper a new potentiometric biosensor for terbuthylazine (TBA, a herbicide widely utilized in agriculture) suitable for this determination in water samples is shown. As previously described, monoclonal antibody (mAb) showing high specificity for the analyte was utilized as biological element to perform the biosensor assay. A light addressable potentiometric sensor (LAPS), measurin...

متن کامل

A disposable microbial based biosensor for quality control in milk.

The food industry needs suitable analytical methods for quality control, that is, methods that are rapid, reliable, specific and cost-effective as current wet chemistries and analytical practices are time consuming and may require highly skilled labor and expensive equipment. The need arises from heightened consumer concern about food composition and safety. The present study was carried out ke...

متن کامل

A Urea Potentiometric Biosensor Based on a Thiophene Copolymer

A potentiometric enzyme biosensor is a convenient detector for quantification of urea concentrations in industrial processes, or for monitoring patients with diabetes, kidney damage or liver malfunction. In this work, poly(3-hexylthiophene-co-3-thiopheneacetic acid) (P(3HT-co-3TAA)) was chemically synthesized, characterized and spin-coated onto conductive indium tin oxide (ITO) glass electrodes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2013