In vivo assessment of diaphragm contraction by ultrasound in normal subjects.
نویسندگان
چکیده
BACKGROUND Ultrasound allows observation of the thickness of the diaphragm in the zone of apposition in vivo during relaxation and maximum inspiratory efforts. METHODS Changes of diaphragm thickness were studied by B mode (two dimensional) ultrasound in 13 healthy men aged 29-54 years in the seated position. A high resolution 7.5 MHz ultrasound transducer was held perpendicular to the chest wall in the line of a right intercostal space between the anteroaxillary and mid-axillary lines to observe the diaphragm in the zone of apposition 0.5-2 cm below the costophrenic angle. The changes of thickness were observed while breath holding at total lung capacity (TLC), functional residual capacity (FRC), and residual volume (RV). At FRC the thickness while relaxing against a closed mouthpiece and during a maximum inspiratory mouth pressure (PImax) manoeuvre was recorded. The thickening ratio (TR) was calculated as TR = thickness during PImax manoeuvre/thickness while relaxing. RESULTS Mean (SD) thickness was 4.5 (0.9) mm at TLC, 1.7 (0.2) mm at FRC, and 1.6 (0.2) mm at RV. During the PImax manoeuvre at FRC mean thickness increased from 1.7 (0.2) mm during relaxation to 4.4 (1.4) mm, while mean PImax and TR were -104 (33) cm H2O and 2.6 (0.7), respectively. There was a high degree of correlation between TR and the pressure achieved during the maximum inspiratory manoeuvre (r = -0.82). CONCLUSIONS Ultrasound provides a non-invasive assessment of diaphragm thickness with change of lung volume and during the PImax manoeuvre which should prove useful in assessing diaphragm mass and contraction in respiratory and muscle disease.
منابع مشابه
Ultrasound monitoring of diaphragm activity in bilateral diaphragmatic paralysis.
Recovery of diaphragm activity after bilateral diaphragmatic paralysis was monitored in a term infant using a mechanical sector scanner fitted with a 5 MHz transducer. The ratio of diaphragmatic excursion during spontaneous breathing and ventilator assistance was used an objective measure for comparison of diaphragmatic activity during recovery. Ultrasound assessment of diaphragm contraction ma...
متن کاملDiaphragm assessment by two dimensional speckle tracking imaging in normal subjects
BACKGROUND Conventionally, ultrasonographic assessment of diaphragm contractility has involved measuring respiratory changes in diaphragm thickness (thickening fraction) using B-mode or caudal displacement with M-mode. Two-dimensional speckle-tracking has been increasingly used to assess muscle deformation ('strain') in echocardiography. We sought to determine in a pilot study if this technolog...
متن کاملرابطه فعالیت الکترومیوگرافی و تغییر ضخامت عضلات دیواره ی طرفی شکم در حین انقباض عضلات کف لگن در زنان سالم
Objective: To asses relationship between abdominal muscles superficial Electromyography (EMG) and ultrasound measurement during Pelvic Floor Muscles (PFM) contraction in healthy people. Methods: 15 healthy women participated in the study. Their abdominal muscles activation (transversus abdominis, internal oblique and external oblique muscles) was measured by EMG and sonography during maximal ...
متن کاملA Giant Ovarian Serous Cystadenoma in Pregnancy: A Case Report
Background:Diagnosis of ovarian mass during pregnancy may be postponed because they may mimic physiological signs of pregnancy. Ovarian masses can lead to complications such as overgrowth, torsion or cyst rupture. Therefore, to inform health providers concerning symptoms, safe diagnostic methods and proper management seem appropriate. Case report: A 19-year-old primigravida was presented to our...
متن کاملThe Effects of Precise Contraction of the Pelvic Floor Muscle Using Visual Feedback on the Stabilization of the Lumbar Region
[Purpose] The purpose of this study is to verify whether precise contraction of the pelvic floor muscle (PFM) using visual feedback actually affects the thickness of abdominal muscles. [Subjects] The subjects were 29 healthy adults in their 20s who consented to participate in this study. [Methods] This study provided visual feedback on PFM using one ultrasound device and identified changes in t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 50 11 شماره
صفحات -
تاریخ انتشار 1995