Evaluation of Cross-Calibrated 68Ge/68Ga Phantoms for Assessing PET/CT Measurement Bias in Oncology Imaging for Single- and Multicenter Trials
نویسندگان
چکیده
Quantitative PET imaging is an important tool for clinical trials evaluating the response of cancers to investigational therapies. The standardized uptake value, used as a quantitative imaging biomarker, is dependent on multiple parameters that may contribute bias and variability. The use of long-lived, sealed PET calibration phantoms offers the advantages of known radioactivity activity concentration and simpler use than aqueous phantoms. We evaluated scanner and dose calibrator sources from two batches of commercially available kits, together at a single site and distributed across a local multicenter PET imaging network. We found that radioactivity concentration was uniform within the phantoms. Within the regions of interest drawn in the phantom images, coefficients of variation of voxel values were less than 2%. Across phantoms, coefficients of variation for mean signal were close to 1%. Biases of the standardized uptake value estimated with the kits varied by site and were seen to change in time by approximately ±5%. We conclude that these biases cannot be assumed constant over time. The kits provide a robust method to monitor PET scanner and dose calibrator biases, and resulting biases in standardized uptake values.
منابع مشابه
Manual production and quality control of 68Ga-PSMA-11 radiopharmaceutical for PET-CT imaging of prostate cancer: optimization and 60 production series experience
Background: 68Ga-PSMA-11, a novel PET radiopharmaceutical, is currently used for imaging of almost all prostate cancers. However, automatic radiolabeling procedures have been recommended. In this research, according to the chemical nature of the PSMA-11, manual, optimized and safe production of this radiopharmaceutical has been investigated and a standard method has been presented to achieve a ...
متن کاملEvaluation of the Possible Utilization of 68Ga-DOTATOC in Diagnosis of Adenocarcinoma Breast Cancer
Objective(s): Studies have indicated advantageous properties of [DOTA-DPhe1 , Tyr3 ] octreotide (DOTATOC) in tumor models and labeling with gallium. Breast cancer is the second leading cause of cancer mortality in women, and most of these cancers are often an adenocarcinoma. Due to the importance of target to non-target ratios in the efficacy of diagnosis, the pharmacokinetic of 68Ga-DOTATOC in...
متن کاملInguino-scrotal bladder hernia: an unexpected finding on 68Ga-PSMA PET/CT
Bladder herniation is an uncommon condition mimicking suspicious metastasis on PET/CT imaging. We report a 67 y/o man with prostate cancer referred for recurrence evaluation with 68Ga-PSMA-11 PET/CT. The scan showed an asymmetric site of intense tracer accumulation in the left inguino-scrotal region with the same SUVmax to the pelvic bladder. Reviewing cross sectional CT i...
متن کاملDiagnostic efficiency of 68Ga-DOTATATE PET/CT as compared to 99mTc-Octreotide SPECT/CT and conventional morphologic modalities in neuroendocrine tumors
Objective(s): In view of somatostatin receptor (SSR) expression on cell membranes of the majority of neuroendocrine tumors (NETs), functional imaging exploiting analogs of SSR alongside the anatomical imaging is the mainstay of this diagnostic modality. In this prospective study, we assessed and directly compared the diagnostic parameters of 68Ga-DOTATATE PET/CT and 99...
متن کاملPreparation and Quality Control of 68Ga-Citrate for PET Applications
Objective(s): In nuclear medicine studies, gallium-68 (68Ga) citrate has been recently known as a suitable infection agent in positron emission tomography (PET). In this study, by applying an in-house produced 68Ge/68Ga generator, a simple technique for the synthesis and quality control of 68Ga-citrate was introduced; followed by preliminary animal studies. Methods: 68GaCl3 eluted from the ge...