Volume Quantification of Acute Infratentorial Hemorrhage with Computed Tomography: Validation of the Formula 1/2ABC and 2/3SH

نویسندگان

  • Wanlin Yang
  • Yulan Feng
  • Yunyun Zhang
  • Jing Yan
  • Yi Fu
  • Shengdi Chen
چکیده

OBJECTIVE To compare the accuracy of formula 1/2ABC with 2/3SH on volume estimation for hypertensive infratentorial hematoma. METHODS One hundred and forty-seven CT scans diagnosed as hypertensive infratentorial hemorrhage were reviewed. Based on the shape, hematomas were categorized as regular or irregular. Multilobular was defined as a special shape of irregular. Hematoma volume was calculated employing computer-assisted volumetric analysis (CAVA), 1/2ABC and 2/3SH, respectively. RESULTS The correlation coefficients between 1/2ABC (or 2/3SH) and CAVA were greater than 0.900 in all subgroups. There were neither significant differences in absolute values of volume deviation nor percentage deviation between 1/2ABC and 2/3SH for regular hemorrhage (P>0.05). While for cerebellar, brainstem and irregular hemorrhages, the absolute values of volume deviation and percentage deviation by formula 1/2ABC were greater than 2/3SH (P<0.05). 1/2ABC and 2/3SH underestimated hematoma volume each by 10% and 5% for cerebellar hemorrhage, 14% and 9% for brainstem hemorrhage, 19% and 16% for regular hemorrhage, 9% and 3% for irregular hemorrhage, respectively. In addition, for the multilobular hemorrhage, 1/2ABC underestimated the volume by 9% while 2/3SH overestimated it by 2%. CONCLUSIONS For regular hemorrhage volume calculation, the accuracy of 2/3SH is similar to 1/2ABC. While for cerebellar, brainstem or irregular hemorrhages (including multilobular), 2/3SH is more accurate than 1/2ABC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study of the factors associated with non-traumatic intracerebral hemorrhage (ICH) in patients with chronic systemic hypertension

Objective: Intracerebral hemorrhage (ICH) following systemic and chronic hypertension is one of the main causes of acute stroke leading to disability and death. Identifying the risk factors in ICH patients can be effective in reducing bleeding and the rates of mortality and disability in these patients. This study was carried out to investigate the factors associated with ICH.Methods: A t...

متن کامل

Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners

Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...

متن کامل

Quantification of Partial Volume Effects in Salivary Glands SPECT Images after Radiation Therapy of Head and Neck Tumors

Introduction: Radical radiation therapy of head and neck cancers may injure the salivary glands and reduce their function. Single-photon emission computed tomography (SPECT) images maybe used to evaluate function post-therapy. However, accurate quantification is hindered by the partial volume effects (PVEs). The present study involved the introduction of a PVEs quantif...

متن کامل

The association of platelet count and mean platelet volume (MPV) index with types of stroke

Background: Stroke is known to be the third most prominent cause of death in the developing countries and the most common debilitating neurologic disease. This study aimed to investigate the association of platelet count (PC) and mean platelet volume (MPV) index with various stroke types. Methods: This cross-sectional study was carried out on patients over the age of 18 years who presented wit...

متن کامل

Siemens primus accelerator simulation using EGSnrc Monte Carlo code and gel dosimetry validation with optical computed tomography system by EGSnrc code

Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013