Another use for the forced air warmer.

نویسنده

  • Robin Cox
چکیده

Plus II Infusion Pump is unique in several important respects. First, according to Abbott, by 2000, this device was the market leader, was used around the world, and accounted for about 75% of all PCA use in the U.S., being used in nearly 4,000 hospitals there.3,4 Furthermore, in 2001, ECRI (formerly the Emergency Care Research Institute, www.ecri.org) stated "this pump has a significant safety problem".5 In late 2002, ECRI continued to receive reports of deaths from programming errors with this pump.6 These deaths were not included in our epidemiological analysis. Second, "the Abbott PCA pumps are the only pumps that ECRI is aware of that can default to a low concentration setting".6 As we explained in our article, this design feature has important safety implications. For example, accepting an initially displayed concentration value of 0.1 mg·mL–1 could lead to an over-infusion of analgesic when a more concentrated drug preparation is used (e.g., 1 mg·mL–1 or 5 mg·mL–1). In contrast, accepting the initially displayed concentration value of 0.0 mg·mL–1, as provided by other PCA pumps described by Dr. Chan, presumably does not lead to any infusion — a fail-safe design feature. In retrospect, given that no study of this type had ever been conducted, analyzing the market leader that has unique design features linked with patient safety seems worthwhile. We agree with Dr. Chan that human factors analyses of other PCA pumps should be conducted and we encourage him and others to do so. If objective scientific evidence eventually confirms Dr. Chan’s opinion that all PCA pumps are equally error-prone, then the threat to patient safety of PCA use is even greater than anticipated; the total number of deaths from concentration programming errors alone could be greater than our initial upper estimate of 667.1 This would make the application of human factors engineering design principles to protect public health even more urgent.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Water warming garment versus forced air warming system in prevention of intraoperative hypothermia during liver transplantation: a randomized controlled trial [ISRCTN32154832]

BACKGROUND: The authors compared two strategies for the maintenance of intraoperative normothermia during orthotopic liver transplantation (OLT): the routine forced-air warming system and the newly developed, whole body water garment. METHODS: In this prospective, randomized and open-labelled study, 24 adult patients were enrolled in one of two intraoperative temperature management groups durin...

متن کامل

The Analysis of the Role of Green Walls in Reduction of Heat Islands in Tehran

With the development of urbanization and population growth in the use of land for construction of residential and industrial areas and other infrastructure and turning to remove more vegetation,construction materials and non-systematic misuse of cities,urban areas have forced some changes that pollution and poor air quality,dehydration,high temperatures are some of its results.The temperature d...

متن کامل

Comparison of two different temperature maintenance strategies during open abdominal surgery: upper body forced-air warming versus whole body water garment.

BACKGROUND A new system has been developed that circulates warm water through a whole body garment worn by the patient during surgery. In this study the authors compared two different strategies for the maintenance of intraoperative normothermia. One strategy used a new water garment warming system that permitted active warming of both the upper and lower extremities and the back. The other str...

متن کامل

Energy and Exergy Analysis of Air PV/T Collector of Forced Convection with and without Glass Cover

In this study, the overall performance of air PV/T, based on energy and exergy analysis has been investigated. Two combinations of air PV/T, which consist of unglazed and glazed air PV/T, are considered. Thermal analysis and numerical calculations were carried out, and the performance parameters of the system for the climate conditions of Kerman were studied. The results are presented in graphs...

متن کامل

The ENSO effect on the tropical Atlantic variability: A regionally coupled model study

[1] A CGCM is used to study the relative roles played by local air-sea interaction and remote ENSO effects on the tropical Atlantic interannual variability. A regional coupling strategy allows full air-sea coupling only over the Atlantic Ocean north of 30!S. Two experiments were conducted, respectively with either climatological or real time boundary conditions prescribed over the uncoupled por...

متن کامل

The Bair Hugger patient warming system in prolonged vascular surgery: an infection risk?

INTRODUCTION Use of the Bair Hugger forced-air patient warming system during prolonged abdominal vascular surgery may lead to increased bacterial contamination of the surgical field by mobilization of the patient's skin flora. METHODS This possibility was studied by analyzing bacterial content in air and wound specimens collected during surgery in 16 patients undergoing abdominal vascular pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Canadian journal of anaesthesia = Journal canadien d'anesthesie

دوره 50 8  شماره 

صفحات  -

تاریخ انتشار 2003