BACKGROUND To date, standardized methods for assessing the disease progression of linear scleroderma of the face (LSF) are lacking. OBJECTIVES We investigated whether Cone Beam Computed Tomography (CBCT) may represent a reliable tool for assessing linear scleroderma of the face (LSF). METHODS Ten patients with LSF and five age-matched controls underwent CBCT assessment. The transverse sections at three anatomic levels of the maxillofacial bones were analyzed. Measurements of soft tissue and total thickness of both affected and unaffected side of the face were made by a standardized methodology. Six raters evaluated CBCTs twice and blindly one from the other. The intra- and inter-rater reliability was assessed by the Intraclass Correlation Coefficient (ICC). RESULTS CBCT was fast and well tolerated by the patients. The inter-rater concordance for the total thickness was excellent, mean ICC 0.75 for patients, 0.89 for controls. The mean ICC for soft tissue thickness was 0.49 for patients, 0.66 for controls. 58.3% of the measurements for patients and 91.2% of those for controls showed excellent ICC results (≥ 0.75). The intra-rater concordance resulted optimal (ICC 0.77-0.99). CONCLUSIONS CBCT is a reliable technique to assess skin and bony changes of LSF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

YIM-O20. Standardization and performance of cone beam ct scan for the evaluation of linear scleroderma of the face

Introduction Up to now, standardized and validated methods for monitoring linear scleroderma of the face are still lacking. Therefore, it is difficult to assess, in these patients, the disease progression both for therapeutic purposes and maxillofacial surgery procedures. The Cone Beam Computed Tomography (CBCT) is an imaging technique that has good sensitivity for both soft and the bony tissue...

متن کامل

مقایسه دقت توموگرافی سه‌بعدی با اشعه مخروطی با توموگرافی کامپیوتری مرسوم در تشخیص بیماری‌های سینوس پارانازال

Background: Paranasal sinus disease is one of the most common problems of patients that refer to ENT centers. Adding to clinical examination imaging plays an important role in diagnosis and treatment. Also the imaging of paranasal sinuses is necessary before surgery. Although computed tomography is the modality of choice for these areas, it has some disadvantages which the most important one is...

متن کامل

Relationship between the dimensions of Sella Turcica with the vertical skeletal pattern of the face on cone beam computed tomography (CBCT) images in an Iranian population.

Background and Aim: Sella turcica is one of the most important orthodontic landmarks in a key point in lateral cephalometric analysis of the patients who need orthodontic treatment. The aim of this research was to investigate the relationship the dimensions of Sella Turcica with the vertical skeletal pattern of the face on cone beam computed tomography images in an Iranian population. Material ...

متن کامل

کاربرد تکنیک تصویربرداری Cone Beam Computed Tomography در تشخیص ودرمان سنترال ژانت سل گرانولوما تومور ؛ گزارش یک مورد

Introduction: Central giant cell granuloma (CGCG) is a relatively rare and non neoplastic tumor with unclear exact etiology that is reported in children. Cone beam computed tomography (CBCT) technique for precise diagnosis and treatment of the jaw lesions is recommended in the recent years. The object of this case-report study is to use CBCT in the diagnosis and treatment of CGCG. Case Repor...

متن کامل

Effect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro

Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2018