Comparison of cardiac output measured by oesophageal Doppler ultrasonography or pulse pressure contour wave analysis.

نویسندگان

  • A Caillard
  • E Gayat
  • A Tantot
  • G Dubreuil
  • E M'Bakulu
  • C Madadaki
  • F Bart
  • D Bresson
  • S Froelich
  • A Mebazaa
  • F Vallée
چکیده

BACKGROUND Maintaining adequate organ perfusion during high-risk surgery requires continuous monitoring of cardiac output to optimise haemodynamics. Oesophageal Doppler Cardiac Output monitoring (DCO) is commonly used in this context, but has some limitations. Recently, the cardiac output estimated by pulse pressure analysis- (PPCO) was developed. This study evaluated the agreement of cardiac output variations estimated with 9 non-commercial algorithms of PPCO compared with those obtained with DCO. METHODS High-risk patients undergoing neurosurgery were monitored with invasive blood pressure and DCO. For each patient, 9 PPCO algorithms and DCO were recorded before and at the peak effect for every haemodynamic challenge. RESULTS Sixty-two subjects were enrolled; 284 events were recorded, including 134 volume expansions and 150 vasopressor boluses. Among the 9 algorithms tested, the Liljestrand-Zander model led to the smallest bias (0.03 litre min(-1) [-1.31, +1.38] (0.21 litre min(-1) [-1.13; 1.54] after volume expansion and -0.13 litre min(-1) [-1.41, 1.15] after vasopressor use). The corresponding percentage of the concordance was 91% (86% after volume expansion and 94% after vasopressor use). The other algorithms, especially those using the Winkessel concept and the area under the pressure wave, were profoundly affected by the vasopressor. CONCLUSIONS Among the 9 PPCO algorithms examined, the Liljestrand-Zander model demonstrated the least bias and best limits of agreement, especially after vasopressor use. Using this particular algorithm in association with DCO calibration could represent a valuable option for continuous cardiac output monitoring of high risk patients. CLINICAL TRIAL REGISTRATION Comité d'éthique de la Société de Réanimation de Langue Française No. 11-356.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Five algorithms that calculate cardiac output from the arterial waveform: a comparison with Doppler ultrasound.

BACKGROUND Different mathematical approaches are used to calculate arterial pulse pressure wave analysis (PPWA) cardiac output. The CardioQ-Combi is a research oesophageal Doppler (COODM) monitor that includes these five fundamental PPWA algorithms. We compared these PPWA cardiac output readings to COODM and suprasternal USCOM Doppler (COUS) over a range of cardiac output values induced by dopa...

متن کامل

Equipment review: New techniques for cardiac output measurement – oesophageal Doppler, Fick principle using carbon dioxide, and pulse contour analysis

Measuring cardiac output is of paramount importance in the management of critically ill patients in the intensive care unit and of 'high risk' surgical patients in the operating room. Alternatives to thermodilution are now available and are gaining acceptance among practitioners who have been trained almost exclusively in the use of the pulmonary artery catheter. The present review focuses on t...

متن کامل

Optimisation of positive and expiratory pressure for maximal delivery of oxygen to tissues using oesophageal Doppler ultrasonography.

OBJECTIVE To assess oesophageal Doppler ultrasonography as a convenient means of optimising positive end expiratory pressure for maximal delivery of oxygen to tissues. DESIGN Measurements of blood flow, arterial oxygen saturation, and cardiac output by thermodilution (when available) at baseline and at 20-30 minutes after each incremental increase (2.5-5.0 cm H2O) in positive and expiratory p...

متن کامل

Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting.

BACKGROUND AND OBJECTIVE During off-pump coronary bypass grafting, surgical manipulation and dislocation of the heart may cause cardiovascular instability. Monitoring of cardiac output facilitates intraoperative haemodynamic management but pulmonary artery catheters are often considered too invasive. Pulse contour analysis and transoesophageal echocardiography could serve as alternatives, but t...

متن کامل

Lack of agreement between esophageal doppler cardiac output measurements and continuous pulse contour analysis during off-pump cardiac surgery

Objective: Transesophageal echo-Doppler cardiac output as well as arterial pulse contour analyses cardiac output are increasingly used for cardiac output monitoring. No data are available whether both techniques may be used interchangeably in patients undergoing cardiac surgery. Design: Prospective, observational study Setting: Operating rooms of a university affiliated hospital. Patients: 30 p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 114 6  شماره 

صفحات  -

تاریخ انتشار 2015