Estimating the accuracy of muscle response testing: two randomised-order blinded studies
نویسندگان
چکیده
BACKGROUND Manual muscle testing (MMT) is a non-invasive assessment tool used by a variety of health care providers to evaluate neuromusculoskeletal integrity, and muscular strength in particular. In one form of MMT called muscle response testing (MRT), muscles are said to be tested, not to evaluate muscular strength, but neural control. One established, but insufficiently validated, application of MRT is to assess a patient's response to semantic stimuli (e.g. spoken lies) during a therapy session. Our primary aim was to estimate the accuracy of MRT to distinguish false from true spoken statements, in randomised and blinded experiments. A secondary aim was to compare MRT accuracy to the accuracy when practitioners used only their intuition to differentiate false from true spoken statements. METHODS Two prospective studies of diagnostic test accuracy using MRT to detect lies are presented. A true positive MRT test was one that resulted in a subjective weakening of the muscle following a lie, and a true negative was one that did not result in a subjective weakening of the muscle following a truth. Experiment 2 replicated Experiment 1 using a simplified methodology. In Experiment 1, 48 practitioners were paired with 48 MRT-naïve test patients, forming unique practitioner-test patient pairs. Practitioners were enrolled with any amount of MRT experience. In Experiment 2, 20 unique pairs were enrolled, with test patients being a mix of MRT-naïve and not-MRT-naïve. The primary index test was MRT. A secondary index test was also enacted in which the practitioners made intuitive guesses ("intuition"), without using MRT. The actual verity of the spoken statement was compared to the outcome of both index tests (MRT and Intuition) and their mean overall fractions correct were calculated and reported as mean accuracies. RESULTS In Experiment 1, MRT accuracy, 0.659 (95% CI 0.623 - 0.695), was found to be significantly different (p < 0.01) from intuition accuracy, 0.474 (95% CI 0.449 - 0.500), and also from the likelihood of chance (0.500; p < 0.01). Experiment 2 replicated the findings of Experiment 1. Testing for various factors that may have influenced MRT accuracy failed to detect any correlations. CONCLUSIONS MRT has repeatedly demonstrated significant accuracy for distinguishing lies from truths, compared to both intuition and chance. The primary limitation of this study is its lack of generalisability to other applications of MRT and to MMT. STUDY REGISTRATION The Australian New Zealand Clinical Trials Registry (ANZCTR; www.anzctr.org.au ; ID # ACTRN12609000455268 , and US-based ClinicalTrials.gov (ID # NCT01066312 ).
منابع مشابه
Exogenous Ketone Supplement Ingestion And Submaximal Exercise Response in Trained, Male Cyclists: A Randomised, Double-blind Study
Background. The acute ingestion of ketone body supplements can improve exercise responses such as oxygen consumption and blood lactate. Additionally, ketone body supplements show increases in circulating βhb concentration, matching those of someone in a state of nutritional ketosis. Studies testing ketone body supplements have reported different results in exercise response and varying gastroin...
متن کاملکاربرد مدل شبکه عصبی مصنوعی در پیشبینی پاسخهای آمیخته بیماری قلبی
Background: In epidemiological and medical studies, sometimes researchers are faced for prediction of two response variables (simultaneously) based on a number of independent variables. When the response variable is mixed, according to established limits and absence of assumption, the classical statistical methods are not enough efficient for classification and prediction goals. The p...
متن کاملAn Android Application for Estimating Muscle Onset Latency using Surface EMG Signal
Background: Electromyography (EMG) signal processing and Muscle Onset Latency (MOL) are widely used in rehabilitation sciences and nerve conduction studies. The majority of existing software packages provided for estimating MOL via analyzing EMG signal are computerized, desktop based and not portable; therefore, experiments and signal analyzes using them should be completed locally. Moreover, a...
متن کاملEndoscopic versus open carpal tunnel release in bilateral carpal tunnel syndrome. A prospective, randomised, blinded assessment.
The advantages and disadvantages of endoscopic compared with open carpal tunnel release are controversial. We have performed a prospective, randomised, blinded assessment in a district general hospital in order to determine if there was any demonstrable advantage in undertaking either technique. Twenty-five patients with confirmed bilateral idiopathic carpal tunnel syndrome were randomised to u...
متن کاملEvaluation of the accuracy of Demirjian method in estimating chronological age
Background and Aim: Age estimation is one of the most important issues in forensic medicine, legal cases and orthodontic treatment. One of the most famous methods which is based on the maturity of teeth for determining dental age is Demirjian method. Due to the inconsistency of the results of studies conducted on different people groups, the present study was done to evaluate the accuracy of D...
متن کامل