A comparison of MR imaging with fast-FLAIR, HASTE-FLAIR, and EPI-FLAIR sequences in the assessment of patients with multiple sclerosis.

نویسندگان

  • M Filippi
  • M A Rocca
  • M Wiessmann
  • S Mennea
  • M Cercignani
  • T A Yousry
  • M P Sormani
  • G Comi
چکیده

BACKGROUND AND PURPOSE Fast fluid-attenuated inversion-recovery (FLAIR) sequences are sensitive for detecting lesions in patients with multiple sclerosis (MS). More rapid fast-FLAIR imaging of the brain can be achieved by the concomitant use of half-Fourier acquisition single-shot turbo spin-echo (HASTE-FLAIR) and echo-planar imaging (EPI-FLAIR). The present study was performed in a large cohort of subjects to assess and compare the number and volume of brain lesions detected by the fast-FLAIR, HASTE-FLAIR, and EPI-FLAIR sequences in patients with MS. METHODS Fast-FLAIR, HASTE-FLAIR, and EPI-FLAIR sequences were obtained from 46 consecutive MS patients. Lesions seen on each type of sequence were counted and classified by consensus by two observers. Lesion volumes were measured using a semiautomated segmentation technique based on local thresholding. RESULTS The quality of the fast-FLAIR images was significantly better than that of HASTE-FLAIR and EPI-FLAIR images. Fast-FLAIR revealed significantly more lesions and higher lesion volumes than did HASTE-FLAIR and EPI-FLAIR. A similar number of large lesions was detected by the three sequences, but HASTE-FLAIR and EPI-FLAIR showed significantly fewer small and intermediate lesions than did fast-FLAIR. The number of lesions seen on HASTE-FLAIR and EPI-FLAIR images was similar. CONCLUSION HASTE-FLAIR and EPI-FLAIR sequences revealed as many large MS lesions as fast-FLAIR. Because their acquisition times are only a fraction of that needed for fast-FLAIR sequences, they may be useful for making a rapid diagnosis of MS in uncooperative patients. Their reduced ability to detect smaller lesions indicates that they should not be used as a routine approach to imaging patients with MS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques

Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is ...

متن کامل

Comparison of MR pulse sequences in the detection of multiple sclerosis lesions.

PURPOSE To compare the sensitivity of conventional spin-echo, fast spin-echo, fast fluid-attenuated inversion recovery (FLAIR), and turbo gradient spin-echo MR sequences in the detection of multiple sclerosis lesions. METHODS Conventional spin-echo, fast spin-echo, fast FLAIR, and turbo gradient spin-echo sequences were performed on a 1.0-T MR imager in seven patients with clinically definite...

متن کامل

Memory dysfunction in multiple sclerosis corresponds to juxtacortical lesion load on fast fluid-attenuated inversion-recovery MR images.

BACKGROUND AND PURPOSE MR imaging is a sensitive diagnostic tool and paraclinical marker of disease activity and prognosis in multiple sclerosis (MS), yet the role of MR imaging of MS is controversial. The aim of this study was to describe the relationship between cognitive function and MS lesion size and position, as shown on comparative images from conventional spin-echo (CSE) and fast fluid-...

متن کامل

Spinal cord lesions in patients with multiple sclerosis: comparison of MR pulse sequences.

PURPOSE To compare T2-weighted conventional spin-echo (CSE), fast spin-echo (FSE), shorttau inversion recovery (STIR) FSE, and fluid-attenuated inversion recovery (FLAIR) FSE sequences in the assessment of cervical multiple sclerosis plaques. METHODS Twenty patients with clinically confirmed multiple sclerosis and signs of cervical cord involvement were examined on a 1.5-T MR system. Sagittal...

متن کامل

Evaluation the FLAIR Sensitivity and DWI Post-inject in Comparison with Delayed Enhancement T1w for Better Detection of Active MS Lesions

Background: Multiple sclerosis (MS) is a chronic, typically progressive and most common autoimmune disease which damaged the central nervous system. According to the reports in 2008, this disorder has affected 2 and 2.5 million people globally. While the reason is not clear, proposed causes for this include immunologic, environmental, infectious and genetic factors, and sexuality. MS can cause ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 20 10  شماره 

صفحات  -

تاریخ انتشار 1999