Biodegradable polymer drug-eluting stents reduce the risk of stent thrombosis at 4 years in patients undergoing percutaneous coronary intervention: a pooled analysis of individual patient data from the ISAR-TEST 3, ISAR-TEST 4, and LEADERS randomized trials.

نویسندگان

  • Giulio G Stefanini
  • Robert A Byrne
  • Patrick W Serruys
  • Antoinette de Waha
  • Bernhard Meier
  • Steffen Massberg
  • Peter Jüni
  • Albert Schömig
  • Stephan Windecker
  • Adnan Kastrati
چکیده

AIMS The efficacy of durable polymer drug-eluting stents (DES) is delivered at the expense of delayed healing of the stented vessel. Biodegradable polymer DES aim to avoid this shortcoming and may potentially improve long-term clinical outcomes, with benefit expected to accrue over time. We sought to compare long-term outcomes in patients treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES). METHODS AND RESULTS We pooled individual patient data from three large-scale multicentre randomized clinical trials (ISAR-TEST 3, ISAR-TEST 4, and LEADERS) comparing biodegradable polymer DES with durable polymer SES and assessed clinical outcomes during follow-up through 4 years. The efficacy endpoint of interest was target lesion revascularization and the safety endpoint of interest was definite stent thrombosis. Out of 4062 patients included in the present analysis, 2358 were randomly assigned to treatment with biodegradable polymer DES (sirolimus-eluting, n= 1501; biolimus-eluting, n= 857) and 1704 patients to durable polymer SES. No heterogeneity across the trials was observed in analyses of the primary and secondary endpoints. At 4 years, the risk of target lesion revascularization was significantly lower among patients treated with biodegradable polymer DES vs. durable polymer SES (hazard ratio 0.82, 95% CI 0.68-0.98, P= 0.029). In addition, the risk of stent thrombosis was significantly reduced with biodegradable polymer DES vs. durable polymer SES (hazard ratio 0.56, 95% CI 0.35-0.90, P= 0.015), driven by a lower risk of very late stent thrombosis (hazard ratio 0.22, 95% CI 0.08-0.61, P= 0.004). In keeping with this, in landmark analysis between 1 and 4 years, the incidence of myocardial infarction was lower for patients treated with biodegradable polymer DES vs. durable polymer SES (hazard ratio 0.59, 95% CI 0.73-0.95, P= 0.031). CONCLUSION Biodegradable polymer DES improve safety and efficacy compared with durable polymer SES during long-term follow-up to 4 years.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term outcomes of biodegradable versus durable polymer drug-eluting stents in patients with acute ST-segment elevation myocardial infarction: a pooled analysis of individual patient data from three randomised trials.

AIMS Arterial plaque rupture and thrombus characterise ST-elevation myocardial infarction (STEMI) and may aggravate delayed arterial healing following durable polymer drug-eluting stent (DP-DES) implantation. Biodegradable polymer (BP) may improve biocompatibility. We compared long-term outcomes in STEMI patients receiving BP-DES vs. durable polymer sirolimus-eluting stents (DP-SES). METHODS ...

متن کامل

Efficacy and Safety of Biodegradable Polymer Biolimus-Eluting Stents versus Durable Polymer Drug-Eluting Stents: A Meta-Analysis

BACKGROUNDS Drug-eluting stents (DES) with biodegradable polymers have been developed to address the risk of thrombosis associated with first-generation DES. We aimed to determine the efficacy and safety of biodegradable polymer biolimus-eluting stents (BES) versus durable polymer DES. METHODS Systematic database searches of MEDLINE (1950 to June 2013), EMBASE (1966 to June 2013), the Cochran...

متن کامل

Ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial.

BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-...

متن کامل

Utilization of Anticoagulant and Antiplatelet Agents Among Patients With Atrial Fibrillation Undergoing Percutaneous Coronary Intervention

coagulant and single antiplatelet therapy (SAPT)) without enhanced risks of vascular events.7,8 In the ISAR-TRIPLE Trial,9 which compared TT of different durations (6 months and 6 weeks), in AF patients undergoing interventions with drug-eluting stents (DES), there were no significant differences in cardiac death, myocardial infarction, definite stent thrombosis, and ischemic stroke. At an indi...

متن کامل

Biodegradable polymer limus-eluting stents are noninferior to permanent polymer-based stents: the ISAR-TEST-4 trial

Background & rationale Over time, it has become clear that despite their dramatic success in tackling coronary restenosis, first generation drug-eluting stents (DES) are associated with a small but significant excess of adverse events late after stent implantation (>12 months), in particular, late stent thrombosis and delayed loss of antirestenotic eff icacy [1–4]. The central process underlyin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 33 10  شماره 

صفحات  -

تاریخ انتشار 2012