Intrastromal corneal ring segment implantation by femtosecond laser for keratoconus correction.

نویسندگان

  • Mohamed H Shabayek
  • Jorge L Alió
چکیده

PURPOSE To report the outcomes after the implantation of intrastromal corneal ring segments (KERARING) aided by femtosecond laser for the correction of keratoconus. DESIGN Prospective consecutive interventional study. PARTICIPANTS Twenty-one eyes of 16 consecutive keratoconic patients with mean age 32+/-10.2 years. Forty-five percent were keratoconus grade I, 20% grade II, 15% grade III, and 20% grade IV. METHODS Intrastromal corneal ring segments KERARING were implanted for keratoconus correction after corneal tunnel creation with the aid of femtosecond laser (IntraLase Corp, Irvine CA). MAIN OUTCOME MEASURES Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), refractive outcome, complete ophthalmologic examination, videokeratography, and corneal higher order aberrations (HOA) were determined or performed before and after surgery at 1 day, 1 week, and 3 and 6 months. In addition, operative and postoperative complications were recorded. RESULTS KERARING implantation significantly increased UCVA from 0.06 to 0.3 (P< or =0.0001), BSCVA from 0.54 to 0.71 (P< or =0.0003), and decreased the spherical equivalent by 2.28 diopters (D) and the average keratometric values (K value) by 2.24 D (P<0.001). There was no significant difference between the 3 and 6 months follow-up. Forty percent (8 eyes with a relatively low RMS of total HOA) showed a nonsignificant increase in the RMS of total HOA and 60% (12 eyes with a relatively higher RMS of total HOA> or =3.0 microm) showed significant (P< or =0.01) decrease in the RMS of total HOA due to a significant (P< or =0.003) reduction in coma and comalike aberrations. The amount of change in corneal curvature (biomechanical response) ranged from a decrease of 18% from its initial value to an increase of 2.75% and was not correlated to any preoperative parameter. Localized infectious keratitis occurred in only 1 eye (4.8%), and incision opacification occurred in 8 eyes (38%). CONCLUSION Intrastromal corneal ring segment implantation with femtosecond laser is an effective method for correcting keratoconus with reduction in corneal HOA in eyes with coma aberration > 3.0 microm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complications of intrastromal corneal ring segment implantation using a femtosecond laser for channel creation: a survey of 850 eyes with keratoconus.

PURPOSE To report complications after the implantation of intrastromal corneal ring segments (Keraring; Mediphacos, Belo Horizonte, Brazil) in keratoconic eyes using a femtosecond laser (IntraLase; Advanced Medical Optics, Santa Ana, California, USA) for channel creation. METHODS Retrospective chart review of 531 patients (850 eyes) who underwent Keraring insertion using a femtosecond laser f...

متن کامل

Intrastromal corneal ring segment implantation with the femtosecond laser in a post-keratoplasty patient with recurrent keratoconus.

A 50-year-old woman had implantation of intrastromal corneal ring segments for recurrent keratoconus 15 years after penetrating keratoplasty. Two segments (0.15 mm and 0.25 mm) were inserted without any intraoperative or postoperative complications, using the femtosecond laser to create the tunnels (superior and inferior). Ten months after the procedure, the uncorrected visual acuity was 20/100...

متن کامل

Single intrastromal corneal ring segment implantation using the femtosecond laser after radial keratotomy in a keratoconic patient.

A 33-year-old woman with irregular astigmatism 6 years after radial keratotomy (RK) for keratoconus was treated with implantation of a single intrastromal corneal ring segment (Keraring) using the femtosecond laser. The segment (0.150 mm thick with a 160-degree arc) was inserted in the steepest area (inferior) with no intraoperative or postoperative complications. Six months postoperatively, th...

متن کامل

Comparative Results in a Combined Procedure of Intrastromal Corneal Rings Implantation and Cross-linking in Patients with Keratoconus: A Retrospective Study

INTRODUCTION Corneal thinning disorders caused by keratoconus often lead to protrusion, irregular astigmatism, and even perforation. Keratoconus, like other corneal ectasia, does not have a known cause. Severe cases of keratoconus may require correction or restoration of tectonic integrity of the cornea by surgical means. Intracorneal ring segments are a new modality in the treatment of corneal...

متن کامل

Predictability of Tunnel Depth for Intrastromal Corneal Ring Segments Implantation Between Manual and Femtosecond Laser Techniques.

PURPOSE To compare the predictability of intrastromal tunnel depth creation for intrastromal corneal ring segments (ICRS) implantation between manual dissection and femtosecond laser using a high-resolution anterior segment optical coherence tomography (AS-OCT). METHODS This multicenter study included patients with keratoconus who had Ferrara-type ICRS implantation at Hospital de Braga using ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmology

دوره 114 9  شماره 

صفحات  -

تاریخ انتشار 2007