Ear oximetry: a noninvasive method for detection of patent foramen ovale: a study comparing dye dilution method and oximetry with contrast transesophageal echocardiography.

نویسندگان

  • V Karttunen
  • M Ventilä
  • M Ikäheimo
  • M Niemelä
  • M Hillbom
چکیده

BACKGROUND AND PURPOSE Patent foramen ovale (PFO) may play an important role as a risk factor for ischemic stroke and some other neurological conditions. There is a need for low-cost and noninvasive methods for the detection of PFO. This study evaluates the accuracy of two simple bedside tests, the dye dilution method and ear oximetry, in the detection of PFO. METHODS Dye dilution curves and ear oximetry recordings with a noninvasive ear densitometer were obtained from consecutive cryptogenic stroke patients referred for contrast transesophageal echocardiography (TEE). All test results were blindly assessed for the presence of PFO. Sensitivity and specificity were calculated with TEE used as a reference method. kappa statistics were used to measure interrater agreement. RESULTS Dye dilution curves were obtained from 67 patients. Dye dilution correctly diagnosed 35 of the 46 patients who had PFO in TEE and all the 21 patients without PFO. Thus, the sensitivity (95% CI) of the dye dilution method was 76% (61% to 87%) and its specificity 100% (84% to 100%). Ear oximetry was done on 83 patients. Oximetry correctly diagnosed 45 of the 53 patients who had PFO in TEE and all of the 30 patients without PFO. Thus, the sensitivity of ear oximetry was 85% (72% to 93%) and its specificity 100% (88% to 100%). The interrater agreement was excellent (kappa value 0.94 for dye dilution and 0.90 for oximetry). CONCLUSIONS Dye dilution and oximetry are both sensitive and specific methods for the detection of PFO. Oximetry has the following primary advantages over the currently available diagnostic methods: it is noninvasive, safe, and inexpensive and causes no discomfort for the patient. We suggest that oximetry could be used as a first-line screening method for PFO in patients with cryptogenic stroke. Ear oximetry also has potential use in epidemiological studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium for detection of patent foramen ovale.

BACKGROUND Patent foramen ovale as a possible stroke risk factor can be diagnosed with transcranial Doppler sonography (TCD) by detecting intravenous contrast medium crossing from the right to the left atrium. The present study evaluates the reliability of this method. SUMMARY OF REPORT We performed TCD and transesophageal echocardiography simultaneously in 50 patients using galactose microbu...

متن کامل

Prevalence of patent foramen ovale and its contribution to hypoxemia in patients with obstructive sleep apnea.

STUDY OBJECTIVES The objectives of this study were (1) to assess the prevalence of patent foramen ovale (PFO) by means of contrast transesophageal echocardiography (TEE) in patients with obstructive sleep apnea, and (2) to determine the potential contribution of right to left interatrial shunting to systemic oxygen desaturation following the performance of Valsalva maneuver. DESIGN Performanc...

متن کامل

Comparison of transthoracic echocardiography using second harmonic imaging, transcranial Doppler and transesophageal echocardiography for the detection of patent foramen ovale in stroke patients.

AIMS The comparison of three imaging methods to determine which is the most accurate and reliable for the detection of right-to-left shunt. METHODS AND RESULTS One hundred and seven patients who were hospitalized for stroke underwent: a transthoracic echocardiography (TTE) using second harmonic, a transcranial Doppler (TCD) and a transesophageal echocardiography (TEE) from August 2003 to Apri...

متن کامل

Effectiveness of pulse oximetry screening for congenital heart disease in asymptomatic newborns.

OBJECTIVE To determine the sensitivity, specificity, predictive value, and accuracy of a program of pulse oximetry screening of asymptomatic newborns for critical congenital cardiovascular malformation (CCVM). METHODS Pulse oximetry was performed on asymptomatic newborns in the well-infant nurseries of 2 hospitals. Cardiac ultrasound was performed on infants with positive screens (saturation ...

متن کامل

An unusual explanation for episodic dyspnea.

An 88-year-old woman with a nonischemic cardiomyopathy, severe kyphoscoliosis, and an implantable cardiac defibrillator presented from her nursing home with dyspnea and hypoxemia. She had several recent hospitalizations for similar symptoms that were attributed to heart failure and pneumonia. On the day of presentation, she had severe dyspnea while eating breakfast. In the emergency department,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 32 2  شماره 

صفحات  -

تاریخ انتشار 2001