Suitable image parameters and analytical method for quantitatively measuring cerebral blood flow volume with phase-contrast magnetic resonance imaging.
نویسندگان
چکیده
The aim of this study was to determine suitable image parameters and an analytical method for phase-contrast magnetic resonance imaging (PC-MRI) as a means of measuring cerebral blood flow volume. This was done by constructing an experimental model and applying the results to a clinical application. The experimental model was constructed from the aorta of a bull and circulating isotonic saline. The image parameters of PC-MRI (repetition time, flip angle, matrix, velocity rate encoding, and the use of square pixels) were studied with percent flow volume (the ratio of actual flow volume to measured flow volume). The most suitable image parameters for accurate blood flow measurement were as follows: repetition time, 50 msec; flip angle, 20 degrees; and a 512 x 256 matrix without square pixels. Furthermore, velocity rate encoding should be set ranging from the maximum flow velocity in the vessel to five times this value. The correction in measuring blood flow was done with the intensity of the region of interest established in the background. With these parameters for PC-MRI, percent flow volume was greater than 90%. Using the image parameters for PC-MRI and the analytical method described above, we evaluated cerebral blood flow volume in 12 patients with occlusive disease of the major cervical arteries. The results were compared with conventional xenon computed tomography. The values found with both methods showed good correlation. Thus, we concluded that PC-MRI was a noninvasive method for evaluating cerebral blood flow in patients with occlusive disease of the major cervical arteries.
منابع مشابه
Analytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging
Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...
متن کاملAutomatic Segmentation of Intracranial Arteries in 4-Dimensional Phase Contrast Magnetic Resonance Angiography
The development of a highly effective phase-contrast magnetic resonance imaging (PC-MRI) technique named phase-contrast vastly undersampled isotropic projection reconstruction (PC-VIPR) has improved the ability to image blood flow in the brain. The technique allows for the acquisition of temporally resolved volume images with high spatial resolution. Utilizing these improvements is of importanc...
متن کاملInvited Methodology of Brain Perfusion Imaging
Numerous techniques have been proposed in the last 15 years to measure various perfusion-related parameters in the brain. In particular, two approaches have proven extremely successful: injection of paramagnetic contrast agents for measuring cerebral blood volumes (CBV) and arterial spin labeling (ASL) for measuring cerebral blood flows (CBF). This review presents the methodology of the differe...
متن کاملEffect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...
متن کاملFunctional imaging of cerebral blood volume using simultaneous measurements of dynamic and xenon computerized tomography (CT).
This report describes a method for measuring regional cerebral blood volume (r-CBV), by simultaneously using dynamic computerized tomography (DCT) and stable Xenon-enhanced CT (Xe CT). Local cerebral blood flow (CBF) was measured using a Xe CT blood sampling method, and mean transit time (MTT) was calculated using DCT after a rapid injection of iodinated contrast material. A functional image of...