Effects of Operating Parameters on the Beam Species of Diii–d Neutral Beam Ion Sources
نویسندگان
چکیده
The DIII–D fusion science research facility employs positive-ion based neutral beam ion sources for plasma heating and current drive experiments. Ion species produced inside the arc chamber of an ion source determine the composition of the neutral beams injected into the plasma and in turn affect the energy deposition along the cross section of the plasma. Arc chamber design and operation schemes are the predominant factors in the ion species mix when an arc discharge is produced inside the arc chamber. When deuterium gas is used for arc discharge three deuterium ion species (atomic D1 + and molecular D2 + and D3 + ) are produced in the arc chamber of the DIII–D neutral beam ion source. Atomic ion D1 + has the highest percentage of the three species, normally about 80% of ions produced. Measurements have shown that both D1 + and D2 + decrease slightly with lower arc power discharges. However, D3 + increases at a higher rate when arc power is reduced. Changing the fraction of the ion species can be beneficial to or meet the needs of some specific plasma experiments. An attempt to manipulate the ion species mix by changing the operating parameters of the arc chamber/ion source has been performed. These operating parameters include filament temperature, arc power, beam energy, and gas flow. Interesting results were obtained which show that arc power is the dominant factor for controlling the species mix. We were not able to significantly change the ion species mix by varying the operating parameters within the operation window when the ion source is operated at constant beam energy. However, the D3 + fraction increased by a factor of three when the ion source was operated at a much lower arc power (for 50 keV beam energy operation) than the higher arc power required for ion source operation with beam energy between 75 to 80 keV.
منابع مشابه
Determination of neutral beam energy fractions from collisional radiative measurements on DIII-D.
Neutral beams based on positive ion source technology are a key component of contemporary fusion research. An accurate assessment of the injected beam species mix is important for determining the actual plasma heating and momentum input as well as proper interpretation of beam-based diagnostics. On DIII-D, the main ion charge-exchange spectroscopy system is used to extract well-resolved intensi...
متن کاملModeling the response of a fast ion loss detector using orbit tracing techniques in a neutral beam prompt-loss study on the DIII-D tokamak.
A numerical model describing the expected measurements of neutral beam prompt-losses by a newly commissioned fast ion loss detector (FILD) in DIII-D is presented. This model incorporates the well understood neutral beam deposition profiles from all eight DIII-D beamlines to construct a prompt-loss source distribution. The full range of detectable ion orbit phase space available to the FILD is u...
متن کاملFast Ion Loss Diagnostics on DIII-D
Sawteeth and tearing modes affect fast ion confinement, while large fast ion densities can drive collective instabilities, including toroidicity-induced Alfvén eigenmodes. Losses of energetic alpha particles in ITER will reduce the alpha heating available to reach ignition, and have the potential to cause major damage to the first wall of ITER. Measurements of the internal mode structures of th...
متن کاملGa-a24514 System Design and Performance for the Upgrade Recent Diii-d Neutral Beam Computer
This operating year marks an upgrade to the computer system charged with control and data acquisition for neutral beam injection system’s heating at the DIII-D National Fusion Facility, funded by the US. Department of Energy and operated by General Atomics (GA), This upgrade represents the third and latest major revision to a system which has been in service over twenty years. The first control...
متن کاملImpact of Various Beam Parameters on Lateral Scattering in Proton and Carbon-ion Therapy
Background: In radiation therapy with ion beams, lateral distributions of absorbed dose in the tissue are important. Heavy ion therapy, such as carbon-ion therapy, is a novel technique of high-precision external radiotherapy which has advantages over proton therapy in terms of dose locality and biological effectiveness.Methods: In this study, we used Monte Carlo method-based Geant4 toolkit to s...
متن کامل