Microscopic conduction in cultured strands of neonatal rat heart cells measured with voltage-sensitive dyes.

نویسندگان

  • V G Fast
  • A G Kléber
چکیده

Microscopic discontinuities in electrical activation were assessed in synthetic strands of neonatal rat myocytes cultured on a growth-directing matrix. An optical method using voltage-sensitive dye (RH-237) and a photodiode technique was used for recordings of membrane potential changes with subcellular resolution. Spatial resolution of the method (diameter of measurement area, 5.5 microns; interdiode distance, 30 microns) allowed for simultaneous measurements of cytoplasmic conduction time within a single cell and junctional conduction time across the cell border. In one-dimensional cell chains, where cells were juxtaposed by end-to-end connections but devoid of lateral connections, propagation of the excitation wave was strongly nonuniform: cytoplasmic conduction time was 38 +/- 30 (mean +/- SD) microseconds (n = 37), whereas junctional conduction time was 118 +/- 40 microseconds (n = 27, P < .0001). A mean delay introduced by a single junction was 80 microseconds, or 51% of conduction time. In two-dimensional strands consisting of several cells in width, which exhibited lateral as well as end-to-end connections, inhomogeneity of conduction was smaller: the cytoplasmic and junctional conduction times were 57 +/- 30 (n = 46) and 89 +/- 40 (n = 48) microseconds, respectively (P < .0001); mean junctional conduction delay was 32 microseconds (22% of conduction time). Mathematical modeling suggested that the averaging effect of lateral connections is caused by lateral convergence of local excitatory current beyond and lateral divergence before end-to-end connections. Our results demonstrate that the current flow through lateral cell-to-cell connections smooth the excitation wave front during longitudinal conduction in myocardial tissue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Slow conduction in cardiac tissue, II: effects of branching tissue geometry.

In cardiac tissue, functional or structural current-to-load mismatches can induce local slow conduction or conduction block, which are important determinants of reentrant arrhythmias. This study tested whether spatially repetitive mismatches result in a steady-state slowing of conduction. Patterned growth of neonatal rat heart cells in culture was used to design unbranched cell strands or stran...

متن کامل

Anisotropic conduction in monolayers of neonatal rat heart cells cultured on collagen substrate.

Anisotropic impulse conduction was studied in neonatal rat heart cell monolayers produced by culturing cells on a growth-directing substrate of collagen. Monolayers consisting of parallel-oriented cells without visible intercellular clefts were selected for experiments; cell lengths and widths were 65.8 +/- 12.5 and 12.2 +/- 3.2 microns (n = 49), respectively. Action potential upstrokes were me...

متن کامل

CHANGE IN CONDUCTION VELOCITY DUE TO 2D FIBER CURVATURE IN CULTURED NEONATAL RAT VENTRICULAR MYOCYTES by ELLIOT BLAKE BOURGEOIS JACK M. ROGERS, COMMITTEE CHAIR

Continuum modeling of two-dimensional curved fiber fields has suggested that fiber curvature modulates conduction velocity (CV) in the myocardium. To verify the existence of this effect in living tissue, we measured CV in macroscopically anisotropic monolayers of cultured neonatal rat ventricular myocytes with controlled fiber curvature. A novel growth-directing substrate was used to produce fi...

متن کامل

Functional reentry in cultured monolayers of neonatal rat cardiac cells.

Previous studies of reentrant arrhythmias in the heart have been performed in computer models and tissue experiments. We hypothesized that confluent monolayers of cardiac cells can provide a simple, controlled, and reproducible experimental model of reentry. Neonatal rat ventricular cells were cultured on 22-mm-diameter coverslips and stained with the voltage-sensitive dye RH-237. Recordings of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 73 5  شماره 

صفحات  -

تاریخ انتشار 1993