Comparison of two regularization methods for soft x-ray tomography at Tore Supra
نویسندگان
چکیده
Soft X-Ray (SXR) emission in the range 0.1 keV – 20 keV is widely used to obtain valuable information on tokamak plasma physics, such as particle transport, magnetic configuration or magnetohydrodynamic (MHD) activity. In particular, 2D tomography is the usual plasma diagnostic to access the local SXR emissivity. The tomographic inversion is traditionally performed from line-integrated measurements of two or more cameras viewing the plasma in a poloidal cross-section, like at Tore Supra (TS). Unfortunately, due to the limited number of measured projections and presence of noise, the tomographic reconstruction of SXR emissivity is a mathematical ill-posed problem. Thus, obtaining reliable results of the tomographic inversion is a very challenging task. In order to perform the reconstruction, inversion algorithms implemented in present tokamaks use a priori information as additional constraints imposed on the plasma SXR emissivity. Among several potential inversion methods, some of them have been identified as well suited to tokamak plasmas. The purpose of this work is to compare two promising inversion methods, i.e. the Minimum Fisher Information (MFI) method already used at TS and planned for WEST configuration, and the alternative 2 nd order Phillips-Tikhonov Regularization (PTR) with smoothness constraints imposed on the second derivative norm. Respective accuracy of both reconstruction methods as well as overall robustness and computational time are studied, using several synthetic SXR emissivity profiles. Finally, a real case is studied through tomographic reconstruction from TS SXR database.
منابع مشابه
Statistical X-ray Computed Tomography Image Reconstruction with Beam Hardening Correction
This paper describes two statistical iterative reconstruction methods for X-ray CT. The rst method assumes a mono-energetic model for X-ray attenuation. We approximate the transmission Poisson likelihood by a quadratic cost function and exploit its convexity to derive a separable quadratic surrogate function that is easily minimized using parallelizable algorithms. Ordered subsets are used to a...
متن کاملDecomposition of supra soft locally closed sets and supra SLC-continuity
In this paper, we introduce two different notions of generalized supra soft sets namely supra A--soft sets and supra soft locally closed sets in supra soft topological spaces, which are weak forms of supra open soft sets and discuss their relationships with each other and other supra open soft sets [{it International Journal of Mathematical Trends and Technology} (IJMTT), (2014) Vol. 9 (1):37--...
متن کاملX-ray scattering tomography for biological applications.
The conventional attenuation contrast imaging does not yield satisfactory sensitivity and specificity for weakly absorbing media, such as biological soft tissues. The x-ray scattering offer an important contrast mechanism to reveal structural features and density fluctuation within an object. This scattering signal carries information at the molecular and supra-molecular level, and has a tremen...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملComparison of no-prior and soft-prior regularization in biomedical microwave imaging
Microwave imaging for medical applications is attractive because the range of dielectric properties of different soft tissues can be substantial. Breast cancer detection and monitoring of treatment response are areas where this technology could be important because of the contrast between normal and malignant tissue. Unfortunately, the technique is unable to achieve the high spatial resolution ...
متن کامل