dE/dx PROTOTYPE TEST*
نویسنده
چکیده
A small prototype of a multiwire dE/dx detector was tested in SLAC's test beam. The basic concept of the detector was similar to the JADE drift cell design. The purpose of the test was to decide on some design parameters for a full size prototype, which is now in construction. Introduction Our motivation was to concentrate on the particle identification below 4 GeV/c which is about the limit of most of the particle distributions at PEP energies. In particular, we wanted to explore the possibility of identifying particles using a dE/dx technique in the HRS magnet. This technique was in a competition, with Cerenkov counters, proposed by the Michigan group.1 The available space allowed us to use only about 70 cm of active length. Our test chamber reported in this paper had 47 samples, each 1.5 cm long. This would allow a reasonable n/e identification below 4 GeV/c, a/p identification below 1.2 GeV/c and above 3 GeV/c, n/k identification below 800 MeV/c, if we would operate at atmospheric pressure. Although some of these regions can be covered by TOF and shower counter techniques, obviously not all particles could be identified by a single device in a multi-prong environment. The type of chamber we decided to investigate resembles the JADE type of detector.2 This type of chamber proved to be useful as a tracking device, however, there are still some questions left about its usefulness as a dE/dx device in the relativistic rise region. We felt that its concept is attractive because in addition to tracking and dE/dx measurement, it has features which limit the number of wires required and it could perform well in a high multiplicity environment. This project had three stages. In the first stage we investigated the properties of several gases in a single sample test chamber, 3 in the second stage we tested the chamber which had full size in the x-y plane and only 10 cm long in the z-direction (most of the data reported in this paper comes from this test), and finally, we constructed a full size chamber, which is now being tested. Description of the Prototype The basic dimensions of the test cell are shown in Fig. 1. The active length of the wires was only 10 cm (z-direction in conventional storage ring sense). Each sample length along the track was 1.5 cm, and there were 47 samples in total. To limit …
منابع مشابه
DE/dx MEASUREMENTS WITH ARGUS
The use of pure heavy hydrocarbons like propane or isobutane has some advantages for drift chaders that measure the specific ionisation for particle identification. With a prototype of the ARGUS drift chamber various gases were tested with a 3 GeV/c electron beam. We found a dE/dx resolution for propane of Fwhm= 10.4% and for isobutane Fwhm = 9.9X, by a factor of + 1.6 better than that for argo...
متن کاملComparison between Oncotype DX test and standard prognostic criteria in estrogen receptor positive early-stage breast cancer Comparação entre o teste Oncotype DX e critérios prognósticos padronizados em câncer de mama receptor de estrogênio positivo em estágio inicial
Objective: To compare the prognosis estimated by standard prognostic criteria versus the prognosis estimated by the Oncotype DX. Methods: A retrospective study was performed on 22 patients with positive estrogen receptor, early-stage breast cancer who had an Oncotype DX recurrence score available. Results: Kappa value between Oncotype DX and standard prognostic criteria was: Adjuvant! (K = 0.09...
متن کاملRapid Health Technology Assessment of Oncotype DX in Patients with Early-Stage Breast Cancer
Introduction: Breast cancer is the most common cancer in women. Patients are treated with chemotherapy initially, and if not chemically treated, the risk of recurrence of the disease increases yearly. Therefore, methods for identifying patients for whom chemotherapy would be most beneficial are very important. The Oncotype DX test is a prognostic assay that predicts the likelihood of breast can...
متن کاملAssociation Between Oncotype DX Recurrence Score and Clinicopathological Variables in Breast Cancer Patients
Introduction: Breast cancer is the most common cancer and the leading cause of cancer-related death in women. Clinicopathological variables are important factors in deciding on breast cancer treatment. This study evaluated the association between the recurrence score generated by the Oncotype DX® 21-gene assay and classic clinicopathological variables. Methods: A single-institution retrospect...
متن کاملFirst beam test of the Frankfurt prototype for the CBM TRD
As one of the key components in the CBM experiment, the Transition Radiation Detector (TRD) will play a significant role in the particle identification. A fast detector with double sided readout chambers[1] and a ALICE type of detector with both drift and amplification regions have been designed for the circumstance of high particle rates. We propose to build a fast detector with an amplificati...
متن کامل