A study of the nitrogen laser power density and some design considerations.

نویسنده

  • A W Ali
چکیده

The laser power density and its time history from a pulsed molecular nitrogen laser are calculated. Their dependence on the fill pressure and on various parameters of an electric circuit, in which the nitrogen gas acts as a variable resistor, is illustrated. It is shown that the peak power density increases in a circuit with low inductance and high capacitor voltage and that the energy density has an optimum at a fill pressure of ~28 Torr. Based on these and the gain calculations, some design considerations are also discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Theoretical Studies of Electrical Characteristics of the Nitrogen Laser

A theoretical analysis of the circuits for a nitrogen laser driven by the Blumlein or capacitor charge transfer transmission line is given in detail. The electrical characteristics of the charge line for a special case of resonant charging are discussed and the effects of various parameters on voltage and current are investigated. By using MICRO-CAP software the transient behavior of the curren...

متن کامل

In-vitro Investigations of Skin Closure using Diode Laser and Protein Solder Containing Gold Nanoshells

Introduction: Laser tissue soldering is a new technique for repair of various tissues including the skin, liver, articular cartilage and nerves and is a promising alternative to suture. To overcome the problems of thermal damage to surrounding tissues and low laser penetration depth, some exogenous chromophores such as gold nanoshells, a new class of nanoparticles consisting of a dielectric cor...

متن کامل

Design of a new asymmetric waveguide in InP-Based multi-quantum well laser

Today, electron leakage in InP-based separate confinement laser diode has a serious effect on device performance. Control of electron leakage current is the aim of many studies in semiconductor laser industry. In this study, for the first time, a new asymmetric waveguide structure with n-interlayer for a 1.325 μm InP-based laser diode with InGaAsP multi-quantum well is proposed and theoreticall...

متن کامل

Laser safety importance in clinical laser applications

Introduction: By introducing of laser systems and their continuous development, a new chapter of laser systems applications in a variety fields including research and clinical science in addition to the therapeutic, diagnostic applications were available for medical professionals in various fields. Most lasers emit radiation with intrinsic probable risks where in laser-tissue i...

متن کامل

Effects of Laser Physical Parameters on Lesion Size in Retinal Photocoagulation Surgery: Clinical OCT and Experimental Study

Introduction: The aim of the present study was to determine burn intensity in retinal laser photocoagulation based on laser parameters; wavelength, power, beam size and pulse duration, using Optical Coherence Tomography (OCT), fundus camera, physical eye model and computer simulation in a clinical study.Materials and Methods: Participants were 10 adult patients between 50-80 years with prolifer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 8 5  شماره 

صفحات  -

تاریخ انتشار 1969