(v) Simulation and measurement of wear in metal-on-metal bearings in vitro- understanding the reasons for increased wear

نویسندگان

  • John Fisher
  • Mazen Al Hajjar
  • Sophie Williams
  • Joanne Tipper
  • Eileen Ingham
  • Louise Jennings
چکیده

A new Stratified Approach For Enhanced Reliability (SAFER) pre-clinical simulation testing of joint prostheses has been described in a preceding paper in this volume. The application of SAFER in vitro simulation and testing to metal-on-metal bearings is described in this review paper. The review aims to provide further understanding of the reasons for, and causes of, increased wear in metal-on-metal hips in a proportion of patients. Variation in positioning (mal-positioning) of the head and cup in hip prostheses results in the head contacting the rim of the cup and producing increased wear. Variation in both translational and rotational positioning has been investigated. Variation in translational positioning of the centres of the head and cup, which is not detected on radiographs, is a frequent occurrence clinically and can result in a substantial increase in wear rate. The variation in translational positioning acts synergistically with variation in rotational positioning to produce substantial increases in wear. These recent findings are consistent with the wear mechanisms and formation of stripe wear reported for ceramic-on-ceramic bearings over a decade ago, and provide insight into the reasons for the variation and increases in the wear rate found clinically in metal-on-metal hips in specific patients, which may cause premature failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wear Performance of Ceramic-On-Metal Hip Bearings

Ceramic-on-metal (CoM) bearings are considered to be a promising alternative to polyethylene-based bearings or hard-on-hard bearings (Ceramic-on-Ceramic (CoC) and Metal-on-Metal (MoM)). Although, CoM shows lower wear rates than MoM, in-vitro wear testing of CoM shows widely varying results. This may be related to limitations of wear-measuring methods. Therefore, the aim of this study was to imp...

متن کامل

The increase in cobalt release in metal-on-polyethylene hip bearings in tests with third body abrasives

Hypersensitivity reactions in patients receiving metal-on-metal hip replacements have been attributed to corrosion products as observed by elevated cobalt and chromium ions in the blood. Although the majority of cases are reported in metal-on-metal, incidences of these reactions have been reported in the metal-on-polyethylene patient population. To date, no in vitro study has considered cobalt ...

متن کامل

Acetabular Cups in 60 mm Metal-on-Metal Bearings Subjected to Dynamic Edge-Loading with 70 Peak-Inclination in 10-Million Cycle Simulator Study

Wear simulation of total-hip arthroplasty (THA) involves hip biomechanics, tribology, bearing designs and cup wear-patterns. This is the first demonstration of cup edge-loading using the “Inverted-cup” test mode. Benefits included, (i) clinically relevant wear-patterns, and (ii) cup inclinations varying from ideal to edge-loaded during each 1-s simulator cycle. The 60 mm head and cup bearings i...

متن کامل

Wear of metal-on-metal 'off-the-shelf' HA-coated/beaded hip bearings

Introduction Wear studies of metal-on-metal (MOM) bearings in hip simulators have historically involved ‘custom’ acetabular cups, i.e. having neither beaded layers nor biological coatings [1]. Such custom designs improve the accuracy of the gravimetric wear assessments. However, it is not always feasible to obtain custom cups for various reasons. Thus, another possibility would be to machine of...

متن کامل

Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge-loading conditions

Metal-on-metal (MoM) bearings have shown low-wear rates under standard hip simulator conditions; however, retrieval studies have shown large variations in wear rates and mechanisms. High-wear in vivo has caused catastrophic complications and has been associated with steep cup-inclination angle (rotational malpositioning). However, increasing the cup-inclination angle in vitro has not replicated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2012