Left ventricular strain and peak systolic velocity: responses to controlled changes in load and contractility, explored in a porcine model
نویسندگان
چکیده
BACKGROUND Tissue velocity echocardiography is increasingly used to evaluate global and regional cardiac function. Previous studies have suggested that the quantitative measurements obtained during ejection are reliable indices of contractility, though their load-sensitivity has been studied in different settings, but still remains a matter of controversy. We sought to characterize the effects of acute load change (both preload and afterload) and change in inotropic state on peak systolic velocity and strain as a measure of LV contractility. METHODS Thirteen anesthetized juvenile pigs were studied, using direct measurement of left ventricular pressure and volume and transthoracic echocardiography. Transient inflation of a vena cava balloon catheter produced controlled load alterations. At least eight consecutive beats in the sequence were analyzed with tissue velocity echocardiography during the load alteration and analyzed for change in peak systolic velocities and strain during same contractile status with a controlled load alteration. Two pharmacological inotropic interventions were also included to generate several myocardial contractile conditions in each animal. RESULTS Peak systolic velocities reflected the drug-induced changes in contractility in both radial and longitudinal axis. During the acute load change, the peak systolic velocities remain stable when derived from signal in the longitudinal axis and from the radial axis. The peak systolic velocity parameter demonstrated no strong relation to either load or inotropic intervention, that is, it remained unchanged when load was systematically and progressively varied (peak systolic velocity, longitudinal axis, control group beat 1-5.72 ± 1.36 with beat 8-6.49 ± 1.28 cm/sec, 95% confidence interval), with the single exception of the negative inotropic intervention group where peak systolic velocity decreased a small amount during load reduction (beat 1-3.98 ± 0.92 with beat 8-2.72 ± 0.89 cm/sec). Systolic strain, however, showed a clear degree of load-dependence. CONCLUSIONS Peak systolic velocity appears to be load-independent as tested by beat-to-beat load reduction, while peak systolic strain appears to be load-dependent in this model. Peak systolic velocity, in a controlled experimental model where successive beats during load alteration are assessed, has a strong relation to contractility. Peak systolic velocity, but not peak strain rate, is largely independent of load, in this model. More study is needed to confirm this finding in the clinical setting.
منابع مشابه
عملکرد سیستولی قلب در بیماران سیروزی کاندید پیوند کبد در مقایسه با گروه کنترل
Background: We assessed different systolic cardiac indices to describe left and right ventricular dysfunction in cirrhotic patients before liver transplantation. Methods: In this case-control study, eighty-one consecutive individuals with the confirmed hepatic cirrhosis and candidate for liver transplantation in the Imam Khomeini Hospital between March 2008 and March 2010 were selected. T...
متن کاملLEFT VENTRICULAR DIASTOLIC ABNORMALITIES IN β-THALASSEMIA MAJOR WITH NORMAL SYSTOLIC FUNCTION
In order to identify left ventricular diastolic function in patients with betathalassemia major and normal systolic function by noninvasive M-mode and Doppler echocardiography, an analytic study was designed in a university hospital in Sari. We have studied 44 patients (23 men and 21 women), mean age 15.48±2.16 (range 12 to 20) and 43 age and sex matched control subjects. Peak flow velocit...
متن کاملSerial changes in left and right ventricular systolic and diastolic dynamics during the first year after an index left ventricular Q wave myocardial infarction.
OBJECTIVES This study quantified serially biventricular emptying and filling after infarction and related these to changes in volume, muscle mass, wall stress and contractility. BACKGROUND There are limited data on serial changes in ventricular dynamics after infarction. METHODS Forty patients had serial electron beam computed tomographic examinations during the first year after index Q wav...
متن کاملLoad-sensitive measures may overestimate global systolic function in the presence of left ventricular hypertrophy: a comparison with load-insensitive measures.
Transgenic animal models have provided a vital insight into the pathogenesis of cardiovascular disease, but functional cardiac assessment is often limited by high heart rates and small heart size. We hypothesized that in the presence of concentric left ventricular (LV) hypertrophy (LVH), load-sensitive measures of contractility may be misinterpreted as overestimating global cardiac function, be...
متن کاملEchocardiographic Evaluation of left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation
Extended abstract Echocardiographic Evaluation of Left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation Cardiovascular disease (CVD) is an important, leading cause of mortality and morbidity in patients with chronic kidney disease (CKD) as well as in renal transplant recipients. Cardiovascular complications become more important in children because of the i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2012