A Method for Assessing the Importance of Body Force on Flow Boiling CHF

نویسندگان

  • Hui Zhang
  • Issam Mudawar
  • Mohammad M. Hasan
چکیده

Experiments were performed to examine the effects of body force on flow boiling CHF. FC-72 was boiled along one wall of a transparent rectangular flow channel that permitted photographic study of the vapor-liquid interface just prior to CHF. High-speed video imaging techniques were used to identify dominant CHF mechanisms corresponding to different flow orientations and liquid velocities. Six different CHF regimes were identified: Wavy Vapor Layer, Pool Boiling, Stratification, Vapor Counterflow, Vapor Stagnation, and Separated Concurrent Vapor Flow. CHF showed significant sensitivity to orientation for flow velocities below 0.2 m/s, where extremely low CHF values where measured, especially with downward-facing heated wall and downflow orientations. High flow velocities dampened the effects of orientation considerably. The CHF data were used to assess the suitability of previous CHF models and correlations. It is shown the Interfacial Lift-off Model is very effective at predicting CHF for high velocities at all orientations. The flooding limit, on the other hand, is useful at estimating CHF at low velocities and for downflow orientations. A new method consisting of three dimensionless criteria is developed to determine the minimum flow velocity required to overcome body force effects on near-saturated flow boiling CHF. @DOI: 10.1115/1.1651532#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental assessment of the effects of body force, surface tension force, and inertia on flow boiling CHF

The interfacial instabilities important to the modeling of critical heat flux (CHF) in reduced-gravity systems are sensitive to even minute body forces, especially for small coolant velocities. Understanding these effects is of paramount importance to both the reliability and safety of two-phase thermal management loops proposed for future space and planetary-based thermal systems. Unfortunatel...

متن کامل

Experimental Study on the Effect of Magnetic Field on Critical Heat Flux of Ferrofluid Flow Boiling in a Vertical Tube

In the present work, the critical heat flux measurements were performed for the subcooled flow boiling of pure water and magnetic nanofluids (i.e., water + 0.01 and 0.1 vol.% Fe‌‌3O4) in a vertical tube. The effect of applying an external magnetic field on the CHF variation was studied experimentally as well. The obtained results indicated that the subcooled flow boiling CHF in the vertical tub...

متن کامل

The Effect of Linear Change of Tube Diameter on Subcooled Flow Boiling and Critical Heat Flux

One of the major industry problems is the flow boiling, where reaching to the critical heat flux (CHF) condition can lead to a temperature jump and damage of the systems. In the present study, the effects of a uniform change in tube diameter on subcooled flow boiling and CHF was numerically investigated. The Euler-Euler model was used to investigate the relationship between the two liquid and v...

متن کامل

A Scale Analysis Based Theoretical Force Balance Model for Critical Heat Flux „CHF... During Saturated Flow Boiling in Microchannels and Minichannels

Accurate prediction of critical heat flux (CHF) in microchannels and minichannels is of great interest in estimating the safe operational limits of cooling systems employing flow boiling. Scale analysis is applied to identify the relevant forces leading to the CHF condition. Using these forces, a local parameter model is developed to predict the flow boiling CHF. The theoretical model is an ext...

متن کامل

A Theoretical Model for Flow Boiling CHF From Short Concave Heaters

Experiments were performed to enable the development of a new theoretical model for the enhancement in CHF commonly observed with flow boiling on concave heaters as compared to straight heaters. High-speed video imaging and photomicrography were employed to capture the trigger mechanism for CHF for each type of heater. A wavy vapor layer was observed to engulf the heater surface in each case, p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004