Evaluation of the accuracy of three techniques used for multiple implant abutment impressions.
نویسندگان
چکیده
STATEMENT OF PROBLEM Movement of pick-up type impression copings inside the impression material during clinical and laboratory phases may cause inaccuracy in transferring the spatial position of implants from the oral cavity to the master cast. As a consequence, the laboratory technician may fabricate a restoration that requires corrective procedures. PURPOSE This in vitro study evaluated the accuracy of 3 different impression techniques using polyether impression material to obtain a master cast for the fabrication of a prosthesis that would fit passively on multiple implants. MATERIAL AND METHODS A machined metal model with 6 implants and abutments and a corresponding, passively fitting, matching metal template were fabricated. A total of 45 medium-consistency polyether impressions (Impregum Penta) of this model were made with pick-up type square impression copings. Three groups of 15 each were made with different impression techniques: in group 1, nonmodified square impression copings were used; in group 2, square impression copings were used and joined together with autopolymerizing acrylic resin before the impression procedure; and in group 3, square impression copings previously airborne particle-abraded and coated with the manufacturer-recommended impression adhesive were used. The matching metal template, which had been passively fit to the metal model so that it encountered no visually perceptible resistance or rocking on the abutments, was used as the control for evaluation of the accuracy of passive fit. A single calibrated and blinded examiner visually evaluated each cast. Positional accuracy of the abutments was numerically assessed with an optical scanner at original magnification x 10, which provided measurements to within 2 microm of the variations of the casts with respect to the horizontal distances between the 2 most posterior abutments and the 2 most anterior abutments. Data were analyzed with a 1-way analysis of variance at alpha=.05, followed by the Student Newman-Keuls method (P=.05). RESULTS Visual examination of the casts from group 1 revealed discrepancies between 1 or more abutments and the metal template. Visual analysis of the master casts from groups 2 and 3 revealed close alignment of the metal template on all 6 abutments. One-way analysis of variance analyzed the numerical data obtained with the optical scanner and revealed significant differences among the 3 impression techniques (P<.001). The Newman-Keuls procedure disclosed significant differences between the groups, with group 2 and 3 casts being significantly more accurate than group 1 casts (P=.05). The distance between abutments 1 and 6 compared to the standard metal model was 33.83 microm (SD +/- 5.4) greater on group 2 casts, 31.72 microm (SD +/- 4.6) greater on group 3 casts, and 78.16 microm (SD +/- 22.14) greater on group 1 casts. Distances between the most anterior abutments were also greater than those recorded on the metal model. The distance was 31.42 microm (SD +/- 7.6) greater on group 2 casts, 30.34 microm (SD +/- 6.4) greater on group 3 casts, and 67.91 microm (SD +/- 15.34) greater on group 1 casts. CONCLUSION Within the limitations of this study, improved accuracy of the master cast was achieved when the impression technique involved square impression copings joined together with autopolymerizing acrylic resin or square impression copings that had been airborne particle-abraded and adhesive-coated.
منابع مشابه
مقایسه دقت تکنیکهای مختلف قالبگیری در قالبهای سطح اباتمنت در ایمپلنتهای دندانی با طرح All-on-4
Background and Aims: Passive fit of prosthetic frameworks is a major concern in implant dentistry. Impression technique is one of the several variables that may affect the outcome of dental implants. The purpose of this study was to compare the three dimensional accuracy of direct and indirect abutment level implant impressions of ALL-ON-4 treatment plan.Materials and Methods: A reference acryl...
متن کاملEvaluation of accuracy of complete-arch multiple-unit abutment-level dental implant impressions using different impression and splinting materials.
PURPOSE This in vitro study evaluated the accuracy of multiple-unit dental implant casts obtained from splinted or nonsplinted direct impression techniques using various splinting materials by comparing the casts to the reference models. The effect of two different impression materials on the accuracy of the implant casts was also evaluated for abutment-level impressions. MATERIALS AND METHOD...
متن کاملComparative Analysis of Dimensional Accuracy of Two Types of Silicone Impression Materials: Optosil and Elite-HD
Statement of the Problem: Understanding about impression materials, their properties, uses and manipulation can guide operators towards having more successful restorations. Purpose: The aim of this in vitro study was to compare the accuracy of a condensation silicone impression material, Optosil, and an addition poly siloxane impression material, Elite-HD. Materials and Method: A laboratory mod...
متن کاملComparison of Different Impression Techniques When Using the All-on-Four Implant Treatment Protocol.
PURPOSE The aim of this in vitro study was to compare the accuracy of two different impression techniques for the All-on-Four implant therapy protocol. MATERIALS AND METHODS An acrylic resin analog for an edentulous maxilla with four internal connection implants (Replace Select, Nobel Biocare) was fabricated according to the All-on-Four protocol. A total of 40 impressions were made with diffe...
متن کاملComparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...
متن کاملEvaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro
Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of prosthetic dentistry
دوره 89 2 شماره
صفحات -
تاریخ انتشار 2003