The Effect of High Intensity Focused Ultrasound Keratoplasty on Rabbit Anterior Segment
نویسندگان
چکیده
Purpose. To evaluate the safety of high-intensity focused ultrasound keratoplasty as a treatment for presbyopia by examining its effect on the rabbit anterior segment. Methods. The right corneas of 36 New Zealand rabbits were treated with HIFU keratoplasty. The animals were sacrificed at 1, 7, 15, 30, 60, and 90 days after operation. Collagen type I, MMP-2, and MMP-9 were evaluated using immunohistochemistry. For the detection of apoptosis, the TUNEL method was applied. The SOD and MDA levels were analyzed with assay kits. Results. Collagen type I, MMP-2, and MMP-9 levels were altered after the operation but returned to normal within 90 days. The apoptotic index (AI) of the corneal cells decreased from 1 to 30 days gradually. No apoptosis was observed in the epithelial cells of the lens, and the SOD and MDA levels were normal at any time point. Conclusion. After HIFU keratoplasty, the histomorphology of the cornea changed, the corneal collagen type I levels decreased, the corneal MMP-2 and MMP-9 levels increased, and the corneal cells underwent apoptosis for a period of time. Ninety days after the operation, the levels returned to normal, and the lenses were not affected. Thus, HIFU presents good biological safety for eyes.
منابع مشابه
Keratorefractive Effect of High Intensity Focused Ultrasound Keratoplasty on Rabbit Eyes
Purpose. To evaluate high intensity focused ultrasound (HIFU) as an innovation and noninvasive technique to correct presbyopia by altering corneal curvature in the rabbit eye. Methods. Eighteen enucleated rabbit eyes were treated with a prototype HIFU keratoplasty. According to the therapy power, these eyes were divided three groups: group 1 (1 W), group 2 (2 W), and group 3 (3 W). The change i...
متن کاملThe effects of ultrasonically induced hyperthermia on experimental tumors in the rabbit eye.
Greene's melanomas, implanted in the anterior chamber of 31 eyes of 19 Dutch rabbits, were treated with hyperthermia induced by high intensity focused ultrasound (HIFU). The percentage necrosis 24 hr after treatment (N) as a function of steady-state intratumor temperature (T) could be described with N(T) = -181.5 + 4.7T (P less than 0.05). The most frequent side effect was a local hemorrhagic k...
متن کاملTherapeutic effects of high intensity focused ultrasound for in patients with benign uterine tumors with regard to lifestyle and obstetric characteristics
Background: The present investigation compared the decrease in the volume of benign tumor before and after High Intensity Focused Ultrasound (HIFU) treatment to evaluate the therapeutic effects of HIFU. in terms of Lifestyle and obstetric characteristics of in patients with Benign Uterine Tumors. Materials and Methods: To collect the data on each patients’ lifestyle and obstetric characteristic...
متن کاملA microsurgical bifurcation rabbit model to investigate the effect of high-intensity focused ultrasound on aneurysms: a technical note
BACKGROUND Recent clinical studies confirmed the high potential of MR-guided focused ultrasound (MRgFUS) in the field of functional neurosurgery. While its ability for precise thermo-ablation within soft tissue is widely recognized, the impact of high-intensity focused ultrasound (HIFU) on larger vessels is less explored. We used a bifurcation aneurysm model in rabbits to investigate the possib...
متن کاملNumerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator
Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2017 شماره
صفحات -
تاریخ انتشار 2017