Quantitative Comparison of 124I PET/CT and 131I SPECT/CT Detectability.

نویسندگان

  • Casper Beijst
  • Jakob W Kist
  • Mattijs Elschot
  • Max A Viergever
  • Otto S Hoekstra
  • Bart de Keizer
  • Hugo W A M de Jong
چکیده

UNLABELLED Radioiodine therapy with (131)I is used for treatment of suspected recurrence of differentiated thyroid carcinoma. Pretherapeutic (124)I PET/CT with a low activity (~1% of (131)I activity) can be performed to determine whether uptake of (131)I, and thereby the desired therapeutic effect, may be expected. However, false-negative (124)I PET/CT results as compared with posttherapeutic (131)I SPECT/CT have been reported by several groups. The purpose of this study was to investigate whether the reported discrepancies may be ascribed to a difference in lesion detectability between (124)I PET/CT and (131)I SPECT/CT and, hence, whether the administered (124)I activity is sufficient to achieve equal detectability. METHODS Phantom measurements were performed using the National Electrical Manufacturers Association 2007 image-quality phantom. As a measure of detectability, the contrast-to-noise ratio was calculated. The (124)I activity was expressed as the percentage of (131)I activity required to achieve the same contrast-to-noise ratio. This metric was defined as the detectability equivalence percentage (DEP). RESULTS Because lower DEPs were obtained for smaller spheres, a relatively low (124)I activity was sufficient to achieve similar lesion detectability between (124)I PET/CT and (131)I SPECT/CT. DEP was 1.5%, 1.9%, 1.9%, 4.4%, 9.0%, and 16.2% for spheres with diameters of 10, 13, 17, 18, 25, and 37 mm, respectively, for attenuation- and scatter-corrected SPECT versus point-spread function (PSF) model-based and time-of-flight (TOF) PET. For no-PSF no-TOF PET, DEP was 3.6%, 2.1%, 3.5%, 7.8%, 15.1%, and 23.3%, respectively. CONCLUSION A relatively low (124)I activity of 74 MBq (~1% of (131)I activity) is sufficient to achieve similar lesion detectability between (124)I PSF TOF PET/CT and (131)I SPECT/CT for small spheres (≤10 mm), since the reported DEPs are close to 1%. False-negative (124)I PET/CT results as compared with posttherapeutic (131)I SPECT/CT may be ascribed to differences in detectability for large lesions (>10 mm) and for no-PSF no-TOF PET, since DEPs are greater than 1%. On the basis of DEPs of 3.5% for lesion diameters of up to 17 mm on no-PSF no-TOF PET, (124)I activities as high as 170 MBq may be warranted to obtain equal detectability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct comparison of 99mTc-PSMA SPECT/CT and 68Ga-PSMA PET/CT in patients with prostate cancer

Objective(s): 99mTc-PSMA SPECT/CT is a cost effective alternative for 68Ga-PSMA PET/CT. The aim of this study was to directly compare these two techniques in patients with prostate cancer. Methods: 28 man with prostate cancer were studied using 99mTc-PSMA SPECT/CT and 68Ga-PSMA PET/CT in a shor...

متن کامل

68Ga-DOTATATE PET/CT Compared with 131I-MIBG SPECT/CT in the Evaluation of Neural Crest Tumors

Objective(s): 68Ga-DOTATATE positron emission tomography (PET)/computed tomography (CT) has shown promising results in imaging of neural crest tumors (NCT). Herein, we compared the performance of 68Ga-DOTATATE PET/CT and 131I-MIBG single photon emission computed tomography (SPECT)/CT in the initial diagnosis, staging and follow-up of pa...

متن کامل

Diagnostic efficiency of 68Ga-DOTATATE PET/CT as compared to 99mTc-Octreotide SPECT/CT and conventional morphologic modalities in neuroendocrine tumors

Objective(s): In view of somatostatin receptor (SSR) expression on cell membranes of the majority of neuroendocrine tumors (NETs), functional imaging exploiting analogs of SSR alongside the anatomical imaging is the mainstay of this diagnostic modality. In this prospective study, we assessed and directly compared the diagnostic parameters of 68Ga-DOTATATE PET/CT and 99...

متن کامل

Recombinant Human Thyroid-Stimulating Hormone Versus Thyroid Hormone Withdrawal in 124I PET/CT-Based Dosimetry for 131I Therapy of Metastatic Differentiated Thyroid Cancer.

Patients with metastatic differentiated thyroid cancer (DTC) may be prepared using either thyroid-stimulating hormone withdrawal (THW) or recombinant human thyroid-stimulating hormone (rhTSH) injections before 131I administration for treatment. The objective of this study was to compare the absorbed dose to the critical organs and tumors determined by 124I PET/CT-based dosimetry for 131I therap...

متن کامل

PET/CT imaging of the diapeutic alkylphosphocholine analog 124I-CLR1404 in high and low-grade brain tumors.

CLR1404 is a cancer-selective alkyl phosphocholine (APC) analog that can be radiolabeled with 124I for PET imaging, 131I for targeted radiotherapy and/or SPECT imaging, or 125I for targeted radiotherapy. Studies have demonstrated avid CLR1404 uptake and prolonged retention in a broad spectrum of preclinical tumor models. The purpose of this pilot trial was to demonstrate avidity of 124I-CLR1404...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 57 1  شماره 

صفحات  -

تاریخ انتشار 2016