Histopathological effect of balloon dilation in a live rabbit: Implications for the pediatric airway.

نویسندگان

  • Vikash K Modi
  • Jiovani M Visaya
  • Robert F Ward
چکیده

OBJECTIVE/HYPOTHESIS To examine the short- and long-term histopathologic changes that occur in the subglottis in response to airway balloon dilation (ABD) with different balloon diameters and inflation pressures. STUDY DESIGN Prospective animal study using forty-two 8-month old New Zealand white rabbits at an academic animal research facility. METHODS Thirty-nine live New Zealand rabbits underwent a single ABD with diameters ranging from 6.0 mm to 10.0 mm and with pressures between 5.0 atmospheres (atm) to 15.0 atm. Animals were euthanized on postoperative days (POD) 1, 7, and 30, and the histopathological changes of the subglottis were examined. Three rabbits served as controls and underwent no ABD. RESULTS The subglottic airway diameter of all specimens measured 5.4 mm. When examining the fracture rate by balloon diameter, we found the following: 0 of 6 (0%) at 6 mm, 0 of 9 (0%) at 7 mm, 6 of 9 (67%) at 8 mm, 8 of 9 (89%) at 9 mm, and 6 of 6 (100%) at 10 mm. There was a statistically significant relationship with the rate of cricoid fracture as balloon diameter increased (P < .0001). All fractures occurred at the anterior cricoid lamina. On POD 1, we found mild ulceration in 5 of 6 (83%) using a 6-mm or 7-mm balloon and in 0 of 6 (0%) using an 8-mm, 9-mm, or 10-mm balloon; and moderate/severe ulceration in 1 of 6 (16.67%) using a 6-mm or 7-mm balloon and in 11 of 11 (100%) using an 8-mm, 9-mm, or 10-mm balloon (P < .0001). Also on POD 1, we found mild edema in 6 of 6 (100%) using a 6-mm or 7-mm balloon and in 5 of 11 (45%) using an 8-mm, 9-mm, or 10-mm balloon; and moderate/severe edema in 0 of 6 (0%) using a 6-mm/7-mm balloon and in 6 of 11 (55%) using an 8-mm, 9-mm, or 10-mm balloon (P =.048). On POD 7, we found fibroplasia in 5 of 6 (83%) using a 6-mm or 7-mm balloon and in 1 of 7 (14%) using an 8-mm, 9-mm, or 10-mm balloon; and moderate/severe fibroplasia in 1 of 6 (17%) using a 6-mm or 7-mm balloon and in 6 of 7 (86%) using an 8-mm, 9-mm, or 10-mm balloon (P =.029). Also on POD7, we found granulation tissue in 0 of 6 (0%) using a 6-mm or 7-mm balloon and in 5 of 7 (71%) using an 8-mm, 9-mm, or 10-mm balloon (P = .021). On POD 30, we found no fibrosis in 0 of 3 (0%) using a 7-mm balloon, mild fibrosis in 1 of 6 (16.67%), and moderate/severe fibrosis in 5 of 6 (83%) using an 8-mm or 9-mm balloon (P = .048). Also on POD 30, we found the mean subglottic cross-sectional luminal area was 23.79 mm(2) with a 7-mm balloon and 29.28 mm(2) with an 8-mm or 9-mm balloon (P = .019). Inflation pressure alone had no correlation with mucosal injury or probability of cricoid fracture. CONCLUSIONS Airway balloon dilation with balloon diameters that exceeded the airway diameter by 2.6 mm was associated with cricoid fractures. All cricoid fractures localized to the anterior cricoid lamina. Balloon diameters larger than the airway diameter by 2.6 mm resulted in a larger subglottic cross-sectional luminal area on POD 30. Airway balloon dilation with balloon diameters that could generate a cricoid fracture created more mucosal injury on POD 0, 1, and 7 than smaller balloon diameters. The histopathological effects of airway balloon dilation observed on POD 0, 1, and 7 resolved by POD 30. When balloon diameter is kept constant, inflation pressure alone had no correlation with mucosal injury or probability of cricoid fracture. LEVEL OF EVIDENCE NA (animal study). Laryngoscope, 125:S1-S11, 2015.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility and mortality of airway balloon dilation in a live rabbit model.

IMPORTANCE Endoscopic balloon dilation is commonly performed in children with airway stenosis, but guidelines are needed for selecting safe and effective balloon inflation parameters. OBJECTIVE To determine the feasibility and safety of airway balloon dilation in live rabbits using a range of balloon diameters and pressures. DESIGN AND SETTING Prospective animal study using 32 adult New Zea...

متن کامل

BALLOON ANGIOPLASTY IN NATIVE AORTIC COARCTATION: RESULT S IN SHIRAZ AND REVIEW OF ARTICLES

Balloon angioplasty for aortic coarctation was introduced in 1979 for the fust time.1 This procedure soon became the choice treatment for restenosis of operated coarctation,2-5 but remains controversial for native (unoperated) coarctation. However, it seems to be rapidly becoming the intervention of choice for relief of unoperated coarctation as well. In this study, we evaluate the outcome ...

متن کامل

Endoscopy Guided Eustachian Tube Balloon Dilation: Our Experiences

Introduction: Eustachian tube (ET) dysfunction is a common clinical entity but its treatment is still challenging to Otorhinolaryngologists. This study is done to know the effectiveness of transnasal endoscopic balloon dilatation of eustachian tube for treatment of chronic eustachian tube dysfunction.   Materials and Methods: It is a retrospective observational study conducted between May 2...

متن کامل

Management of complex glottic stenosis in children with recurrent respiratory papillomatosis.

OBJECTIVES To describe our management of complex glottic stenosis in tracheotomy dependent children with severe recurrent respiratory papillomatosis. METHODS Retrospective chart review at a tertiary care children's hospital. RESULTS Three children with complex glottic stenosis secondary to severe recurrent respiratory papillomatosis were treated at our institution since 2011. Two patients h...

متن کامل

Balloon Dilation

Background. Atherosclerosis has been associated with loss of artery wall distensibility in human cadavers and in experimental animal models, giving it the lay term "hardening of the arteries." Methods and Results. To assess the effect of calcification on arterial distensibility, balloon pressure and volume were recorded during dilation of calcified aortas in Watanabe heritable hyperlipidemic (W...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Laryngoscope

دوره 125 Suppl 6  شماره 

صفحات  -

تاریخ انتشار 2015