Comments on Van Deemter plot in high speed countercurrent chromatography

نویسندگان

  • Alain Berthod
  • Alain Foucault
  • Alain
  • Berthod
چکیده

An inaccuracy in the computation of the linear mobile phase velocity rendered the whole content of a recently published article, Q.Z. Du, P.D. Wu, Y, Ito, J. Liq. Chromatogr. & Rel. Technol., 23(19), 2929 (2000), erroneous. Since the stationary phase volume was given, the correct mobile phase velocity values were computed and the new values for the Van Deemter plots of three compounds are listed. It is concluded that the 1.5 mL/min flow rate, corresponding to the minimum of the Van Deemter plots, or the maximum efficiency, does not justify calling the technique High Speed CCC since three hours are needed to develop the chromatogram.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Medium-pressure Liquid Chromatography

Preparative HPLC 5}30 '20 2}20 0.01}1 High purity solvent required Higher resolution See also: II/Chromatography: Countercurrent Chromatography and High-Speed Countercurrent Chromatography: Instrumentation. Chromatography: Liquid: Countercurrent Liquid Chromatography. III/Alkaloids: Gas Chromatography; High-Speed Countercurrent Chromatography; Liquid Chromatography; Thin-Layer (Planar) Chromato...

متن کامل

Ultra Performance Liquid Chromatography (UPLC): An Introduction

Michael E. Swartz, Ph.D. Principal Scientist, Waters Corporation, Milford, Massachusetts, e-mail [email protected]. igh performance liquid chromatography (HPLC) is a proven technique that has been used in laboratories worldwide over the past 30-plus years. One of the primary drivers for the growth of this technique has been the evolution of packing materials used to effect the separatio...

متن کامل

Gas Chromatography I. Retention, Efficiency and Resolution Purpose

Purpose In this experiment you will examine the effect of temperature on retention in isothermal gas chromatography, and use this information to determine the heat of solution of the solute in the stationary phase and to determine the temperature for optimum retention. You will also examine the effect of flow rate on efficiency and construct a van Deemter plot, and determine the flow rate for o...

متن کامل

Separation of catalpol from Rehmannia glutinosa Libosch. by high-speed countercurrent chromatography.

The bioactive iridoid component catalpol was successfully separated by high-speed countercurrent chromatography with high purity from the partially purified crude extract of Rehmannia glutinosa. A polar two-phase solvent system composed of ethyl acetate-n-butanol-water (2:1:3, v/v/v) was selected by thin-layer chromatography and run on a preparative scale where the lower aqueous phase was used ...

متن کامل

Countercurrent Chromatography and High Speed Countercurrent Chromatography: Instrumentation

Engelsma M, KokWT and Smit HC (1990) Selective determination of trace levels of phenol in river water using electrochemical concentration modulation. Journal of Chromatography 506: 201}210. Fister JC, Jacobson C and RamseyM (1999) Ultra sensitive cross correlation electrophoresis on microdevices. Analytical Chemistry 71: 4460}4464. Kaljurand M and KuK llik E (1989) Computerized Multiple Input C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001