Power Quality in Railway Traction and Compensation by Combining Shunt Hybrid Filter and TCR

نویسندگان

  • N. Gunavardhini
  • M. Chandrasekaran
چکیده

This paper analyses the quality of electricity in railway traction. Power quality characteristics have been measured as a case study in a traction sub-station in Tamil Nadu, India, where 1400 KVAR capacitor bank is installed. The actual data has been obtained through direct supply of traction load. Harmonics and various power quality problems are generated through the load of current. The emerging power problems need attention to rectify the "polluting" sites. Issues are measured by providing power quality analyzer and compared with IEEE standards 5191992. Simulation has been done to improve the power quality issues such as harmonics, power factor and reactive power by using a combination of shunt hybrid filter and Thyrsitor Control Rectifier.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power Quality Improvement in Traction Power Supply Networks

AC railway traction loads are usually huge single phase loads. As a result, a significant amount of Negative Sequence Current (NSC) is injected into utility grid. Moreover, harmonics and consumption ofreactive power are further power quality problems that the supply network is encountering. In this paper, acompensation strategy with the aid of Railway Power Conditioner (RPC) is proposed to over...

متن کامل

Research on Synthesis Control of Power Quality for Electrified Railway

This paper analyzes necessity of synthesis control of power quality aiming at characteristics of traction power supply system for electrified railway. According to the fact that the existing power quality control, the measure and means were introduced, analyzed and compared in detailed. From reliability, technology and economy point, the project of synthesis Control was put forward on power qua...

متن کامل

Rating Reduction and Optimized DC-Link Voltage of the HPQC in Co-Phase Traction Power System

Electric traction trains are huge non-linear single-phase loads influencing adversely on power quality parameters on the grid side. Hybrid power quality conditioner (HPQC) has been utilized to compensate current unbalance, harmonics, and low power factor in the co-phase traction system simultaneously. By incrementing the traction load, the rating of the HPQC increases and may constraints its ap...

متن کامل

Harmonic Elimination of 25 kV AC Electric Railways Utilizing a New Hybrid Filter Structure

Thyristor rectifiers are widely used in electric railways in order to control the speed. As a consequence of their usage in addition to substantial input lead current, an enormous amount of harmonics is injected into the grid. To avoid such harmonics as well as reactive power compensation, reactive power hybrid filters consisting of active and passive filters are utilized. Regarding different p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017