Liquid chromatographic-fluorescence determination of ammonia from nitrogenase reactions: a 2-min assay.

نویسنده

  • J L Corbin
چکیده

The analytical potential of the reaction of ammonia with o-phthalaldehyde mercaptoethanol reagent at pH 7 (an atypical fluorescence) has already been demonstrated. This, coupled with additional findings reported here, has led to an ammonia determination well suited to nitrogenase studies. As a result, large numbers of samples can be rapidly analyzed by high-pressure liquid chromatrography methods under mild conditions and without prior microdiffusion. Neither sodium dithionite (or other components of the usual nitrogenase assay), nor alternative substrates (cyanide, azide, methyl isonitrile), nor their products (methylamine, dimethylamine, hydrazine) interfere. High-pressure liquid chromatography showed that the fluorescent "product" of the o-phthalaldehyde mercaptoethanol reagent-ammonia reaction was, in fact, more than just a single compound. Despite this, once the proper solvent composition was found, high-pressure liquid chromatography with a small inexpensive C(18) "guard" column proved quite fast and reproducible for this measurement. Fluorescence response to ammonia was linear to at least 40 nmol/ml. A previous problem, long-term stability of the fluorescence, was solved by running the reactions in the dark. Background ammonia in the buffer could be substantially reduced by an analogous o-phthalaldehyde mercaptoethanol reagent reaction, using t-butyl mercaptan, and solvent extraction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A High-Performance Liquid Chromatographic Assay for the Determination of Losartan in Plasma

A rapid and sensitive HPLC method was developed for determination of losartan in plasma. Losartan was extracted from plasma by a two-step extraction procedure using chloroform as extracting solvent in acidic medium. HPLC analysis was performed on a cyano reversed-phase column using phosphate buffer (pH 4.3), acetonitrile (750:250, v/v) as mobile phase with a flow rate of 0.9 mL/min. Sodium dicl...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 47 5  شماره 

صفحات  -