Ex vivo accuracy of three electronic apex locators using different apical file sizes.
نویسندگان
چکیده
This study evaluated the accuracy of three electronic apex locators (Root ZX, Novapex, and Justy II) in root canal length determinations using different apical file sizes, considering the apical constriction (AC) and the major foramen (MF) as anatomic references. The diameter of the apical foramina of 40 single-rooted teeth was determined by direct visual measurement and the master apical file was established. Electronic measurements were then performed using 3 instruments: the selected master apical file (adjusted file), one size smaller (intermediate file), and two sizes smaller (misfit file). The distances from the tip of files fixed in the canals to the MF and to the AC were measured digitally. Precision at AC and at MF for the misfit, intermediate and adjusted apical files was as follows: 80%/88%/83% and 78%/83%/95% (Root ZX); 80%/85%/80% and 68%/73%/73% (Novapex); and 78%/80%/78% and 65%/78%/70% (Justy II). Considering the mean discrepancies, statistically significant differences were found only for the adjusted file at MF, with Root ZX presenting the best results at MF. The chi-square test showed significant differences between the acceptable measurements at AC and at MF for the Justy II and Novapex (± 0.5 mm) regardless of file adjustment. Under the conditions of the present study, all devices provided acceptable electronic measurements regardless of file adjustment, except for Root ZX which had its performance improved significantly when the precisely fit apical file was used. Justy II and Novapex provided electronic measurements nearest to the AC.
منابع مشابه
In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination
In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...
متن کاملAccuracy of three electronic apex locators compared with digital radiography: an ex vivo study.
INTRODUCTION This study compared (1) the accuracy of three different electronic apex locators (EALs) in detecting the apical foramen ex vivo under clinical conditions; (2) the accuracy of digital radiography and EALs in determining the working length (WL) with visible control under a microscope; and (3) the precision of #10, #15, and #20 K-files in electronic measurements. METHODS The length ...
متن کاملEx vivo evaluation of the accuracy of two electronic apex locators during root canal length determination in primary teeth.
AIM To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. METHODOLOGY One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the ac...
متن کاملA comparison between two electronic apex locators: an ex vivo investigation.
AIM To compare ex vivo the performance of the Apex Finder and the Root ZX apex locators, with and without irrigant, in canals having different diameters. METHODOLOGY Sixty canals in 60 teeth were prepared using stainless steel hand files and 0.04 taper NiTi rotary instruments. During preparation the narrowest diameter of the canal was transported to the apical root surface. The canals were ir...
متن کاملEx vivo accuracy of Root ZX II, Root ZX Mini and RomiApex A-15 apex locators in extracted vital pulp teeth.
The objective of this study was to compare, ex vivo, the accuracy of three electronic apex locators (EALs), Root ZX II, Root ZX Mini and RomiApex A-15, in detecting the apical foramen (AF). Forty extracted single-Rooted human teeth with vital pulp were used in this study. After access preparation, the Root canal length of each tooth was measured by placing a #10 file until the tip was visible a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian dental journal
دوره 23 3 شماره
صفحات -
تاریخ انتشار 2012