OH column abundance over Table Mountain Facility, California: Intraannual variations and comparisons to model predictions for 19972001

نویسندگان

  • Franklin P. Mills
  • Richard P. Cageao
  • Stanley P. Sander
  • Mark Allen
  • Yuk L. Yung
  • Ellis E. Remsberg
  • James M. Russell
  • Ulf Richter
چکیده

[1] Measurements of the OH column abundance over the Jet Propulsion Laboratory’s Table Mountain Facility (TMF) have been made since July 1997 at 10 –80 solar zenith angle using a Fourier transform ultraviolet spectrometer. The measured OH column at any solar zenith angle is typically larger in the afternoon than in the morning. The variations observed in the OH column abundance appear to result from changes in atmospheric conditions on a daily or longer timescale. The larger observed variations are statistically significant. Sensitivity coefficients describing how the OH column abundance is expected to change in response to changes in the concentrations of H2O, O3, NO, CO, and CH4 have been calculated on the basis of an analytic model. On the basis of these sensitivity coefficients and Halogen Occultation Experiment observations of O3, the net sensitivity of the OH column abundance to variations in O3 should be close to zero. The observed OH column abundance over TMF increased by about 25% from July 1997 to December 2001. This interannual trend in OH column abundance is not consistent with calculations that incorporate observed trends in H2O and O3 and is at least a factor of 2 larger than the calculated difference between solar minimum and maximum. Comparisons between measured and calculated normalized OH column abundances suggest that the sensitivity of OH to variations in H2O may be a factor of 2 larger than predicted in present models and that there is some other major driver for the observed variability in the OH column abundance that was not included in the present analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

OH column abundance over Table Mountain Facility, California: AMPM diurnal asymmetry

[1] Observations of the OH column abundance have been made by the Fourier Transform Ultraviolet Spectrometer at the JPL Table Mountain Facility (TMF) near Los Angeles since July 1997. In the January 1998– December 2003 data set we used five OH lines to derive the OH column abundance in the atmosphere. This data set was used to quantify the OH morning/afternoon asymmetry (AMPMDA). An analysis of...

متن کامل

Diurnal variation of midlatitudinal NO3 column abundance over table mountain facility, California

The column abundance of NO3 was measured over Table Mountain Facility, CA (34.4N, 117.7W) from May 2003 through September 2004, using lunar occultation near full moon with a grating spectrometer. The NO3 column retrieval was performed with the differential optical absorption spectroscopy (DOAS) technique using both the 623 and 662 nm NO3 absorption bands. Other spectral features such as Fraunho...

متن کامل

Validation of Aura Microwave Limb Sounder OH measurements with Fourier Transform UltraViolet Spectrometer total OH column measurements at Table Mountain, California

[1] The first seasonal and interannual validation of OH measurements from the Aura Microwave Limb Sounder (MLS) has been conducted using ground-based OH column measurements from the Fourier Transform Ultra-Violet Spectrometer (FTUVS) over the Jet Propulsion Laboratory’s Table Mountain Facility (TMF) during 2004–2007. To compare with FTUVS total column measurements, MLS OH vertical profiles over...

متن کامل

New Raman Water Vapor and Temperature Lidar at JPL Table Mountain Facility: Optimization, Validations and Sonde Intercomparison

Jet Propulsion Laboratory currently operates lidar systems at Table Mountain Facility (TMF), California (34.4◦N, 117.7◦W at 2300m) and Mauna Loa Observatory (MLO), Hawaii (19.5◦N, 155.6◦W at 3400m) under the Network for the Detection of Atmospheric Composition Change (NDACC, formerly NDSC). To complement existing NDACC lidars at TMF, which acts as a primary site for inter-comparisons, a new wat...

متن کامل

High-Resolution Fourier-Transform Ultraviolet-Visible Spectrometer for the Measurement of Atmospheric Trace Species: Application to OH.

A compact, high-resolution Fourier-transform spectrometer for atmospheric near-ultraviolet spectroscopy has been installed at the Jet Propulsion Laboratory's Table Mountain Facility (34.4 degrees N, 117.7 degrees W, elevation 2290 m). This instrument is designed with an unapodized resolving power near 500,000 at 300 nm to provide high-resolution spectra from 290 to 675 nm for the quantification...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003