Geometrical characteristics after Y-stenting of the basilar bifurcation.
نویسندگان
چکیده
PURPOSE We aimed to investigate the angular changes after Y-stenting of the basilar bifurcation aneurysms. METHODS A total of 19 patients (age range, 27-80 years; mean age, 52.5 years) underwent Y-stent coiling for basilar bifurcation aneurysm. Three vascular angles (α, β1, β2) were measured in the anteroposterior plane. β1 and β2 represented the angles between the basilar artery and the proximal P1 segments of the right and left posterior cerebral arteries, respectively. α represented the complementary angle between the β1 and β2 angles. Angles were measured before and after stent deployment. Diameters of the basilar artery and P2 segment of the posterior cerebral artery were measured at both sides. Correlation between vascular diameter and angular change of the basilar bifurcation was investigated. RESULTS Statistically significant α, β1, and β2 angle changes were found after stent deployment (P < 0.001). There was no statistically significant relationship between the diameter of the basilar artery and the α, β1, β2 angle changes (P > 0.05). There was no statistically significant relationship between the diameter of the posterior cerebral artery and the β angle change (P > 0.05). We found a statistically significant inverse correlation between pre-stent β angle and post-stent angle change (right side, P = 0.008; left side, P < 0.001). CONCLUSION Y-stenting narrows the effective neck and straightens the vascular bifurcation angle. Most of the angular remodeling occurs on the side that had a more acute angle before stent deployment.
منابع مشابه
Double-barrel Y-configuration Stenting for Flow Diversion of a Giant Recurrent Basilar Apex Aneurysm with the Pipeline Flex Embolization Device
Giant basilar apex aneurysms are extremely challenging to successfully manage. The Pipeline Flex embolization device (PFED) is a new generation flow-diverting stent with a modified delivery system which allows resheathing of the stent after partial deployment. We describe a case of double-barrel Y-configuration stenting of a giant, recurrent basilar apex aneurysm using the PFED. A 73-year-old m...
متن کامل114 Treatment of Bifurcation Aneurysms Using Single Stent-Coiling With Relation to Aneurysm Configuration: A Cohort Study of Two Academic Institutions in the United States.
INTRODUCTION Stent-coiling of bifurcation aneurysms has significantly expanded the spectrum of aneurysms amenable to endovascular therapy. A variety of techniques have evolved to deal with wide-necked bifurcation aneurysms such as Y-stenting and WEB embolization device. In our 2 institutions, we have primarily used a single stent coiling to treat most bifurcation aneurysms. We present a large s...
متن کاملY-configured double stent-assisted coil embolization with double microcatheter technique for complex basilar bifurcation aneurysm.
Y-configured double stent technique is useful for coil embolization of a bifurcation wide neck aneurysm while preserving the patency of the two important vessels. However, if the important vessels emanating directly from the aneurysm comprised four vessels, two vessels not deployed, Y-stents might not be preserved with the Y-stent technique by itself. We report a case treated with Y-configured ...
متن کاملImpact of stenting technique and bifurcation anatomy on long-term outcomes of PCI for distal unprotected left main coronary disease.
OBJECTIVES We aimed to assess the associations of stenting strategy and bifurcation anatomy with outcomes of percutaneous coronary intervention (PCI) for distal unprotected left main (ULM) coronary disease. BACKGROUND There are limited and conflicting data regarding long-term outcomes associated with stenting strategies for PCI of distal ULM coronary disease. METHODS Patients undergoing non...
متن کاملعوامل پیشگوییکننده انسداد شاخه جانبی و عوارض زودرس آن به دنبال آنژیوپلاستی عروق کرونر
Background: Percutaneous Coronary Intervention (PCI) for bifurcated lesions is associated with a low rate of success and high rate of complications compared to such treatment of lesions of most other morphologies. Symptoms occurring at the time of procedure caused by PCI may require additional angiography with or without stenting through stent struts, which subsequently increases risks of reste...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Diagnostic and interventional radiology
دوره 21 6 شماره
صفحات -
تاریخ انتشار 2015