Progress in aberration-corrected high-resolution transmission electron microscopy using hardware aberration correction.
نویسنده
چکیده
The design and construction of a double-hexapole aberration corrector has made it possible to build the prototype of a spherical-aberration corrected transmission electron microscope dedicated to high-resolution imaging on the atomic scale. The corrected instrument, a Philips CM200 FEG ST, has an information limit of better than 0.13 nm, and the spherical aberration can be varied within wide limits, even to negative values. The aberration measurement and the corrector control provide instrument alignments stable enough for materials science investigations. Analysis of the contrast transfer with the possibility of tunable spherical aberration has revealed new imaging modes: high-resolution amplitude contrast, extension of the point resolution to the information limit, and enhanced image intensity modulation for negative phase contrast. In particular, through the combination of small negative spherical aberration and small overfocus, the latter mode provides the high-resolution imaging of weakly scattering atom columns, such as oxygen, in the vicinity of strongly scattering atom columns. This article reviews further lens aberration theory, the principle of aberration correction through multipole lenses, aspects for practical work, and materials science applications.
منابع مشابه
Lifetime of Optical States in Transmission Electron Microscopy
In the recent two decades the technique of high-resolution transmission electron microscopy (HRTEM) experienced an unprecedented progress through the introduction of hardware aberration correctors and by the improvement of the achievable resolution to the sub-Ångström level. With this development, also the required precision level to measure and adjust the optical properties of transmission ele...
متن کاملAberration corrected STEM by means of diffraction gratings.
In the past 15 years, the advent of aberration correction technology in electron microscopy has enabled materials analysis on the atomic scale. This is made possible by precise arrangements of multipole electrodes and magnetic solenoids to compensate the aberrations inherent to any focusing element of an electron microscope. Here, we describe an alternative method to correct for the spherical a...
متن کاملAmplitude Contrast Imaging: High Resolution Electron Microscopy Using a Spherical and Chromatic Aberration Corrected TEM
High-resolution transmission electron microscopy (HREM) is a powerful technique to study materials at atomic resolution. For a conventional TEM, the Scherzer defocus is typically used to maximize phase contrast and resolution. For a TEM with a spherical aberration (Cs) image corrector, Jia et al introduced the negative Cs imaging (NCSI) method to balance the contrast and resolution [1]. This pa...
متن کاملCurrent and future aberration correctors for the improvement of resolution in electron microscopy.
The achievable resolution of a modern transmission electron microscope (TEM) is mainly limited by the inherent aberrations of the objective lens. Hence, one major goal over the past decade has been the development of aberration correctors to compensate the spherical aberration. Such a correction system is now available and it is possible to improve the resolution with this corrector. When high ...
متن کاملNew possibilities with aberration-corrected electron microscopy.
Unlike light microscopy, where resolution is diffraction limited, the achievable resolution of electron microscopes is limited by lens aberrations so severe that the practical resolution is orders of magnitude worse than the diffraction limit. About 10 years ago, the first practical electron lens spherical aberration correctors were developed, and in the past decade, their performance, versatil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada
دوره 12 3 شماره
صفحات -
تاریخ انتشار 2006