Use of the new contact force sensing ablation catheter dramatically reduces fluoroscopy time during atrial fibrillation ablation procedures
نویسندگان
چکیده
OBJECTIVES To study the impact of contact force (CF) sensing on fluoroscopy, procedure, left atrial (LA) and ablation times and number of ablations during atrial fibrillation (AF) ablation. BACKGROUND Catheter ablation is an effective treatment for symptomatic AF. Recently a new ablation catheter providing real-time CF has been approved for use. METHODS A nested case-control study was performed comparing radiofrequency ablation of AF using the irrigated CF-sensing ThermoCool SmartTouch catheter versus open-irrigated ThermoCool SF catheter (Biosense Webster, Inc., Diamond Bar, California). Demographic and procedure data were obtained and student t-test was used to compare data between groups. RESULTS Thirty consecutive adult patients were included with 15 patients in each group. Mean fluoroscopy time was significantly lower in CF group (19.4 ± 8 vs 40.7 ± 8 min, p < 0.0001). LA time was significantly lower in CF group (151.7 ± 44 vs 185.7 ± 35 min, p = 0.01). There were no significant differences in procedure time between CF and SF groups (204 ± 37 vs 207 ± 36 min) and ablation time (121 ± 32 vs 122 ± 37 min). When patients who only underwent pulmonary vein isolation (PVI) were compared, fluoroscopy time was significantly lower in CF group (18 ± 9 vs 37.8 ± 5 min, p < 0.0001) as was LA time (141.4 ± 39 vs 171.8 ± 30 min, p = 0.04). Fluoroscopy time was also significantly lower in CF subgroup with additional ablation (20.9 ± 7 vs 44.9 ± 10 min, p < 0.001). CONCLUSION Use of CF-sensing catheter significantly reduced fluoroscopy and LA times during AF ablation with similar acute efficacy.
منابع مشابه
Contact Force and Atrial Fibrillation Ablation.
Catheters able to measure the force and vector of contact between the catheter tip and myocardium are now available. Pre-clinical work has established that the degree of contact between the radiofrequency ablation catheter and myocardium correlates with the size of the delivered lesion. Excess contact is associated with steam pops and perforation. Catheter contact varies within the left atrium ...
متن کاملContact force-guided catheter ablation for the treatment of atrial fibrillation: a meta-analysis of randomized, controlled trials
Contact force (CF) sensing technology allows real-time monitoring during catheter ablation for atrial fibrillation (AF). However, the effect of CF sensing technology on procedural parameters and clinical outcomes still needs clarification. Because of the inconsistent results thus far in this area, we performed a meta-analysis to determine whether CF sensing technology can improve procedural par...
متن کاملCatheter–tissue contact force for pulmonary veins isolation: a pilot multicentre study on effect on procedure and fluoroscopy time
AIMS Catheter-tissue contact is critical for effective lesion creation in radiofrequency catheter ablation (RFCA). In a multicentre prospective study, we assessed the effect of direct contact force (CF) measurement on acute procedural parameters during RFCA of atrial fibrillation (AF). METHODS AND RESULTS A new open-irrigated tip catheter with CF sensing (SmartTouch™, Biosense Webster Inc.) w...
متن کاملA systematic review of the effectiveness of catheter ablation NavX mapping system for treatment of the cardiac arrhythmia
Background: Catheter ablation is widely used for treatment of atrial fibrillation. The use of fluoroscopic and non-fluoroscopic mapping systems in catheter ablation is common. This study conducted to investigate the safety and effectiveness of Navx non-fluoroscopic mapping system. Methods : In this study, the appropriate electronic databases including Cochrane Library and Ovid Medline searc...
متن کاملContact force mapping during catheter ablation for atrial fibrillation: procedural data and one-year follow-up
INTRODUCTION Pulmonary vein isolation (PVI) is the state-of-the-art treatment of atrial fibrillation (AF). Pulmonary vein reconnection is one of the main mechanisms of AF recurrence after ablation. Catheter-tissue contact is essential for effective ablation lesions. The aim of this study was to evaluate the impact of catheter contact monitoring during PVI on AF recurrence rate. MATERIAL AND M...
متن کامل