Effects of dextran on five biuret-based procedures for total protein in serum.
نویسندگان
چکیده
We evaluated the effect of dextran on values for total protein in serum as measured by the biuret method with five widely used automated instruments: the American Monitor Parallel; the Du Pont aca II; the Roche Cobas-Bio; the Kodak Ektachem 400; and the Beckman Astra 8. Dextran concentrations as great as 25 or 30 g/L had relatively little or no influence on total protein measurements by the latter three instruments. Dextran concentrations exceeding 6 g/L caused falsely low results with the aca, whereas the Parallel gave falsely high results when the dextran concentration exceeded 2 g/L. The aca total protein procedure could be protected from the interference by dextran concentrations up to 30 g/L by injecting 0.4-0.8 mL of ethylene glycol directly into the reagent pack before sampling. However, we could not eliminate the interference with the Parallel procedure by any simple means; we thus recommend that it not be used for measuring total protein in serum samples from patients who are being treated with dextran.
منابع مشابه
Effect of water salinity on total protein and electrophoretic pattern of serum proteins of grass carp, Ctenopharyngodon idella
In this study the effects of water salinity on serum total protein and its components in grass carp were investigated. The aim of this study was to determine the effect of salinity tolerance of fish on total serum protein level and its components as an indicator of liver and kidney activity. One hundred and twenty grass carp were divided into four groups, randomly. The first three groups were r...
متن کاملElimination of dextran interference in serum protein determinations.
Serum containing dextrans of average molecular weight 40,000 (“Dextran-40”), 70,000 (“Dextran-70”), or 75,000 (“Dextran-75”) become turbid when biuret reagent is added (1, ). This interference has been overcome (3) by first precipitating serum proteins with trichioroacetic acid before applying the biuret reaction. Positive interference of these drugs with the o-toluidine glucose assay has also ...
متن کاملAlbumin-based or albumin-linked calibrators cause a positive bias in serum proteins assayed by the biuret method.
BACKGROUND Assay of total serum protein by the biuret method calibrated with albumin standards according to the reference method provides results with a positive bias approximately 3%-5% exceeding the total error of 3.4% allowable for total protein in serum analysis made by analysers using two-part reagents and short-term procedures. METHODS We used two types of two-part biuret reagents utili...
متن کاملA candidate reference method for determination of total protein in serum. I. Development and validation.
We developed a candidate Reference Method for measuring total serum protein by use of the biuret reaction. The method involves a previously described biuret reagent (Clin. Chem. 21: 1159, 1975) and Standard Reference Material (SRM) 927 bovine albumin (National Bureau of Standards) as the standard. At 25 degrees C, color development for 30 or 60 min provides identical serum protein values. Gluco...
متن کاملPrevention of interference by dextran with biuret-type assay of serum proteins.
In assay of serum proteins by use of the biuret reaction, dextran can cause turbidity by formation of an insoluble complex of dextran with copper and tartrate (or EDTA) in strongly alkaline solution. Whether or not the turbidity occurs depends on the tartrate concentration: turbidity is maximal at about 10 g/L, absent at 20 g/L or more, and only slight and delayed at 4 g/L. Two biuret reagents,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 31 12 شماره
صفحات -
تاریخ انتشار 1985