MR-guided transcranial focused ultrasound safely enhances interstitial dispersion of large polymeric nanoparticles in the living brain
نویسندگان
چکیده
Generating spatially controlled, non-destructive changes in the interstitial spaces of the brain has a host of potential clinical applications, including enhancing the delivery of therapeutics, modulating biological features within the tissue microenvironment, altering fluid and pressure dynamics, and increasing the clearance of toxins, such as plaques found in Alzheimer's disease. Recently we demonstrated that ultrasound can non-destructively enlarge the interstitial spaces of the brain ex vivo. The goal of the current study was to determine whether these effects could be reproduced in the living brain using non-invasive, transcranial MRI-guided focused ultrasound (MRgFUS). The left striatum of healthy rats was treated using MRgFUS. Computer simulations facilitated treatment planning, and targeting was validated using MRI acoustic radiation force impulse imaging. Following MRgFUS treatments, Evans blue dye or nanoparticle probes were infused to assess changes in the interstitial space. In MRgFUS-treated animals, enhanced dispersion was observed compared to controls for 70 nm (12.8 ± 0.9 mm3 vs. 10.6 ± 1.0 mm3, p = 0.01), 200 nm (10.9 ± 1.4 mm3 vs. 7.4 ± 0.7 mm3, p = 0.01) and 700 nm (7.5 ± 0.4 mm3 vs. 5.4 ± 1.2 mm3, p = 0.02) nanoparticles, indicating enlargement of the interstitial spaces. No evidence of significant histological or electrophysiological injury was identified. These findings suggest that transcranial ultrasound can safely and effectively modulate the brain interstitium and increase the dispersion of large therapeutic entities such as particulate drug carriers or modified viruses. This has the potential to expand the therapeutic uses of MRgFUS.
منابع مشابه
First non-invasive thermal ablation of a brain tumor with MR guided focused ultrasound
Magnetic resonance-guided focused ultrasound surgery (MRgFUS) allows for precise thermal ablation of target tissues. While this emerging modality is increasingly used for the treatment of various types of extracranial soft tissue tumors, it has only recently been acknowledged as a modality for noninvasive neurosurgery. MRgFUS has been particularly successful for functional neurosurgery, whereas...
متن کاملUltrasound-mediated delivery of brain-penetrating nanoparticles across the blood-tumor barrier
Background/introduction The intact blood-brain barrier (BBB) presents a major obstacle for drug delivery to the brain. In addition, both high interstitial pressure and a nanoporous electrostatically charged tissue composition, produce a “blood-tumor barrier” (BTB), further complicating the treatment of diseases like glioblastoma. Focused ultrasound (FUS) in conjunction with microbubbles (MB) ha...
متن کاملI-46: Repeat Transvaginal Ultrasound-Guided Ovarian Interstitial Laser Treatment Improved the Anovulatory Status in Women with Polycystic Ovarian Syndrome
Background: To assess the effectiveness of repeated transvaginal ultrasound-guided ovarian interstitial laser treatment in the management of anovulatory patients with polycystic ovary syndrome (PCOS). Materials and Methods: A retrospective study was performed in our department on 27 anovulatory PCOS women who failed to respond to the first ultrasound-guided transvaginal ovarian interstitial las...
متن کاملSimple MRI metrics contribute to optimal care of the patient with multiple sclerosis.
Cancer Res 2012;72:3652– 63 7. McDannold N, Clement GT, Black P, et al. Transcranial magnetic resonance imaging-guided focused ultrasound surgery of brain tumors: initial findings in 3 patients. Neurosurgery 2010;66:323–32 8. Jeanmonod D, Werner B, Morel A, et al. Transcranial magnetic resonance imaging-guided focused ultrasound: noninvasive central lateral thalamotomy for chronic neuropathic p...
متن کاملOptimization of a four-coil array arrangement for brain therapy by MR-guided transcranial focused ultrasounds
A particularly critical issue for brain therapy with transcranial high-power focused ultrasound (HIFU) is to optimize the accuracy and rapidity of the temperature follow-up during the heating. MRI is a well-suited candidate for temperature monitoring since it offers several parameters such as the proton resonance frequency shift. Up-to-now, temperature scans were achieved using the standard bod...