Compact grating interferometer for producing photoresist gratings with incoherent light.

نویسندگان

  • D Post
  • K Patorski
  • P Ning
چکیده

An achromatic interferometer was developed to produce 1200-lines/mm crossed-line photoresist gratings with a mercury arc light source. It is a compact reflection system of outstanding stability. Alignment procedures are described. The most stringent requirement, coplanar alignment of two folding gratings, was accomplished with the aid of a Twyman-Green interferometer. The grating interferometer produced crossed-line photoresist gratings with first-order diffraction efficiency exceeding 20%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heat treatment for reduction of surface roughness on holographic gratings.

Controlled postdevelopment heat treatment of the photoresist polymer used in the preparation of holographic gratings has been shown to enhance the diffraction efficiency of gratings and reduce the scattering losses. We prove this effect by analyzing the resonant reflection spectra of a waveguide grating and observing the reduction in the arc-shaped light scattering associated with the excitatio...

متن کامل

Grating pseudo-imaging with polychromatic and finite extension sources.

The pseudo-imaging process in a system consisting of two periodic gratings and illuminated by an incoherent polychromatic and finite extension source placed at a finite distance from the gratings is studied. An analytical expression of the irradiance distribution on a plane, also located at a finite distance from the gratings, has been obtained from previous results on monochromatic illuminatio...

متن کامل

Harmonically-related diffraction gratings-based interferometer for quadrature phase measurements.

We demonstrate the use of shallow diffraction gratings for quadrature phase interferometry. A single shallow diffraction grating-based Michelson interferometer yields only trivial (0(o) or 180(o) ) phase shift between different output ports. In comparison, a combination of two parallel shallow diffraction gratings can be useful to achieve desired phase shifts (e.g., 90 (o) for quadrature phase ...

متن کامل

Efficient generation of large diffraction gratings with a grating interferometer.

The advantages of a grating interferometer for the generation of large diffraction gratings are demonstrated. In a one- and a two-stage process, high-quality gratings of 120 and 200 mm, respectively, were made with optics no larger than 50 mm together with an argon-ion laser with no line narrowing or beam stabilization and a rotating diffuser for improved beam uniformity.

متن کامل

Tilt sensitivity of the two-grating interferometer.

Fringe formation in the two-grating interferometer is analyzed in the presence of a small parallelism error between the diffraction gratings assumed in the direction of grating shear. Our analysis shows that with partially coherent illumination, fringe contrast in the interference plane is reduced in the presence of nonzero grating tilt with the effect proportional to the grating tilt angle and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 26 6  شماره 

صفحات  -

تاریخ انتشار 1987