The first technique for non-invasive measurements of volumetric ophthalmic artery blood flow in humans.

نویسندگان

  • F Orge
  • A Harris
  • L Kagemann
  • K Kopecky
  • C W Sheets
  • E Rechtman
  • M Zalish
چکیده

AIM To validate the first non-invasive measurements of volumetric ophthalmic artery blood flow in humans. METHODS The ophthalmic arteries of healthy normal adults were examined by Advanced Technology Laboratories (ATL, a subsidiary of Phillips Medical Systems Inc) high definition imaging (HDI) 5000 colour Doppler imaging ultrasound with a 5-12 MHZ probe. A group of 14 subjects for experiment 1 and a group of 10 subjects for experiments 2 and 3 were selected, with the examined eye chosen randomly. Peak systolic velocities (PSV) and end diastolic velocities (EDV) of the ophthalmic artery and central retinal artery were measured and recorded. Cineloops (cinegraphic videos) of the ophthalmic arteries were then recorded with the ATL HDI 5000 and values for ophthalmic artery blood flow were produced offline using experimental analysis software. Multiple regression analysis was used to compare blood flow measurements with PSV and EDV measurements in the ophthalmic artery. In two follow up experiments, intraobserver variation in obtaining cineloops and the interanalyser variability in cineloop analysis were studied. RESULTS Volumetric flow correlated with ophthalmic artery PSV and EDV (p = 0.02, r(2) = 0.5). There was no correlation with the cental retinal artery. The intraobserver coefficient of variation in obtaining cineloops was 29.89% for blood flow, 19.07% for diameter, and 22.27% for velocity. The coefficients of variation of the measurements of the two cineloop analysers were 40.21% for blood flow, 22.71% for diameter, and 26.34% for velocity. CONCLUSION Cineloop analysis produces ophthalmic artery flow measurements which correlate with PSV and EDV, suggesting validity. The intraobserver variation and cineloop analyser variation were found to be in the acceptable range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SCIENTIFIC CORRESPONDENCE The first technique for non-invasive measurements of volumetric ophthalmic artery blood flow in humans

Aim: To validate the first non-invasive measurements of volumetric ophthalmic artery blood flow in humans. Methods: The ophthalmic arteries of healthy normal adults were examined by Advanced Technology Laboratories (ATL, a subsidiary of Phillips Medical Systems Inc) high definition imaging (HDI) 5000 colour Doppler imaging ultrasound with a 5–12 MHZ probe. A group of 14 subjects for experiment ...

متن کامل

MHD Flow of Blood through Radially Non-symmetric Stenosed Artery: a Hershcel-Bulkley Model (RESEARCH NOTE)

The purpose of this study is to develop a mathematical model for studying the magnetic field effect on blood flow through an axially non-symmetric but radially symmetric atherosclerotic artery. Herschel-Bulkley equation has been taken to represent the non-Newtonian character of blood. The response of magnetic field, stenosis height, shape parameter on velocity, volumetric flow rate in stenotic ...

متن کامل

An implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery

With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...

متن کامل

Mathematical Modeling of Micropolar Blood Flow in a Stenosed Artery Under the Body Acceleration and Magnetic Field

Blood flow is modeled as non-Newtonian micropolar fluid. The non-linear governing equations of continuum and momentum in the cylindrical coordinate are being discretized using a finite difference approach and have been solved iteratively ,through Crank-Nicolson method. The blood velocity distribution, volumetric flow rate and Resistance to blood flow at the stenosis throat are computed for vari...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 86 11  شماره 

صفحات  -

تاریخ انتشار 2002