Dysphagia bedside screening for acute-stroke patients: the Gugging Swallowing Screen.

نویسندگان

  • Michaela Trapl
  • Paul Enderle
  • Monika Nowotny
  • Yvonne Teuschl
  • Karl Matz
  • Alexandra Dachenhausen
  • Michael Brainin
چکیده

BACKGROUND AND PURPOSE Acute-onset dysphagia after stroke is frequently associated with an increased risk of aspiration pneumonia. Because most screening tools are complex and biased toward fluid swallowing, we developed a simple, stepwise bedside screen that allows a graded rating with separate evaluations for nonfluid and fluid nutrition starting with nonfluid textures. The Gugging Swallowing Screen (GUSS) aims at reducing the risk of aspiration during the test to a minimum; it assesses the severity of aspiration risk and recommends a special diet accordingly. METHODS Fifty acute-stroke patients were assessed prospectively. The validity of the GUSS was established by fiberoptic endoscopic evaluation of swallowing. For interrater reliability, 2 independent therapists evaluated 20 patients within a 2-hour period. For external validity, another group of 30 patients was tested by stroke nurses. For content validity, the liquid score of the fiberoptic endoscopic evaluation of swallowing was compared with the semisolid score. RESULTS Interrater reliability yielded excellent agreement between both raters (kappa=0.835, P<0.001). In both groups, GUSS predicted aspiration risk well (area under the curve=0.77; 95% CI, 0.53 to 1.02 in the 20-patient sample; area under the curve=0.933; 95% CI, 0.833 to 1.033 in the 30-patient sample). The cutoff value of 14 points resulted in 100% sensitivity, 50% specificity, and a negative predictive value of 100% in the 20-patient sample and of 100%, 69%, and 100%, respectively, in the 30-patient sample. Content validity showed a significantly higher aspiration risk with liquids compared with semisolid textures (P=0.001), therefore confirming the subtest sequence of GUSS. CONCLUSIONS The GUSS offers a quick and reliable method to identify stroke patients with dysphagia and aspiration risk. Such a graded assessment considers the pathophysiology of voluntary swallowing in a more differentiated fashion and provides less discomfort for those patients who can continue with their oral feeding routine for semisolid food while refraining from drinking fluids.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using the gugging swallowing screen (GUSS) for dysphagia screening in acute stroke patients.

Aspiration pneumonia from dysphagia following stroke presents significant morbidity and mortality in that population. Dysphagia screening before oral intake has been a standard of care for years, but there is a lack of consensus on the best screening tool. The Gugging Swallowing Screen (GUSS) is presented as a potentially better alternative to other dysphagia screens due to its safer progressio...

متن کامل

Dysphagia Bedside Screening for Acute-Stroke Patients

Background and Purpose—Acute-onset dysphagia after stroke is frequently associated with an increased risk of aspiration pneumonia. Because most screening tools are complex and biased toward fluid swallowing, we developed a simple, stepwise bedside screen that allows a graded rating with separate evaluations for nonfluid and fluid nutrition starting with nonfluid textures. The Gugging Swallowing...

متن کامل

Early Dysphagia Screening by Trained Nurses Reduces Pneumonia Rate in Stroke Patients: A Clinical Intervention Study.

BACKGROUND AND PURPOSE Dysphagia is a common stroke symptom and leads to serious complications such as aspiration and pneumonia. Early dysphagia screening can reduce these complications. In many hospitals, dysphagia screening is performed by speech-language therapists who are often not available on weekends/holidays, which results in delayed dysphagia assessment. METHODS We trained the nurses...

متن کامل

Validation of a dysphagia screening tool in acute stroke patients.

BACKGROUND Although many dysphagia screening tools exist, none has high sensitivity and reliability or can be administered quickly with minimal training. OBJECTIVE To design and validate a swallowing screening tool to be used by health care professionals who are not speech language pathologists to identify dysphagia and aspiration risk in acute stroke patients. METHODS In a prospective stud...

متن کامل

Dysphagia Screening Tool in Acute Stroke Patients

Background Although many dysphagia screening tools exist, none has high sensitivity and reliability or can be administered quickly with minimal training. Objective To design and validate a swallowing screening tool to be used by health care professionals who are not speech language pathologists to identify dysphagia and aspiration risk in acute stroke patients. Methods In a prospective study of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 38 11  شماره 

صفحات  -

تاریخ انتشار 2007