Real time mass flow rate measurement using multiple fan beam optical tomography.
نویسندگان
چکیده
This paper presents the implementing multiple fan beam projection technique using optical fibre sensors for a tomography system. From the dynamic experiment of solid/gas flow using plastic beads in a gravity flow rig, the designed optical fibre sensors are reliable in measuring the mass flow rate below 40% of flow. Another important matter that has been discussed is the image processing rate or IPR. Generally, the applied image reconstruction algorithms, the construction of the sensor and also the designed software are considered to be reliable and suitable to perform real-time image reconstruction and mass flow rate measurements.
منابع مشابه
Solid/Gas Concentration Measurements Using Multiple Fan Beam Optical Tomography
The application of optical sensors in process tomography involves using non-intrusive sensors to obtain vital information in order to produce images from the dynamic characteristics of a process system. Multiple fan beam projection technique here is defined as allowing more than one emitter to transmit light at the same time using the switch-mode fan beam method. For the thirty-two pairs of sen...
متن کاملHardware Implementation of Multiple Fan Beam Projection Technique in Optical Fibre Process Tomography
The main objective of this project is to implement the multiple fan beam projection technique using optical fibre sensors with the aim to achieve a high data acquisition rate. Multiple fan beam projection technique here is defined as allowing more than one emitter to transmit light at the same time using the switch-mode fan beam method. For the thirty-two pairs of sensors used, the 2-projection...
متن کاملUsability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter
Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...
متن کاملECT and LS-SVM Based Void Fraction Measurement of Oil-Gas Two-Phase Flow
A method based on Electrical Capacitance Tomography (ECT) and an improved Least Squares Support Vector Machine (LS-SVM) is proposed for void fraction measurement of oil-gas two-phase flow. In the modeling stage, to solve the two problems in LS-SVM, pruning skills are employed to make LS-SVM sparse and robust; then the Real-Coded Genetic Algorithm is introduced to solve the difficult problem...
متن کامل[Measurements of cerebral blood flow by the noninvasive microsphere method with 123I-IMP and fan beam collimator: comparison with the continuous arterial blood sampling method].
PURPOSE AND METHODS The noninvasive microsphere (NIMS) method quantifies cerebral blood flow with N-isopropyl-p-[123I]-iodoamphetamine (123I-IMP) without blood sampling of a patient, but when a fan beam collimator is used for collecting raw data in single photon emission computed tomography (SPECT), the procedure is complicated because we have to change the collimator. In phantom and clinical s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- ISA transactions
دوره 47 1 شماره
صفحات -
تاریخ انتشار 2008