RES, an expert system for the set-up and interpretation of a ruggedness test in HPLC method validation Part 3: The evaluation
نویسنده
چکیده
منابع مشابه
ICES, an expert system for the set-up and interpretation of a ruggedness test in HPLC method validation Part 1: The ruggedness test in HPLC method validation
Van Leeuwen, J.A., Buydens, L.M.C., Vandeginste, B.G.M., Kateman, G., Schoenmakers, P.J. and Mulholland, M. 1991. RES, an expert system for the set-up and inte~retation of a ruggedness test in HPLC method validation. Part 1: The ruggedness test in HPLC method validation. Chemomeirics and Intelligent Lnboratory Systems, 10: 331-347. In method validation, an intralaboratory repeatability study an...
متن کاملRES, an expert system for the set-up and interpretation of a ruggedness test in HPLC method validation Part 2: The ruggedness expert system
متن کامل
Automatic Interpretation of UltraCam Imagery by Combination of Support Vector Machine and Knowledge-based Systems
With the development of digital sensors, an increasing number of high-resolution images are available. Interpretation of these images is not possible manually, which necessitates seeking for practical, fast and automatic solutions to solve the environmental and location-based management problems. The land cover classification using high-resolution imagery is a difficult process because of the c...
متن کاملDeveloped Method Application for Nitrite Ion (NO2¯ ) Analysis of Tib -186 Macrophage Like Cell Lines by Rapid Isocratic HPLC System with High Sensitive Glassy Carbon Electrochemical Detector
A rapid isocratic method of high performance liquid chromatography system (HPLC) with a glassy carbon working electrode of electrochemical detector is set up for quantitative detection of trace amount of nitrite ion (NO2¯) in aqueous protein containing cell lysate, cell media, plasma, serum, urine and other body fluids. The solid extraction reversed phase cartridges ...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017