Evaluation of central venous pressure monitoring in children undergoing craniofacial reconstruction surgery.

نویسندگان

  • Paul A Stricker
  • Elaina E Lin
  • John E Fiadjoe
  • Emily M Sussman
  • Eric Y Pruitt
  • Huaqing Zhao
  • David R Jobes
چکیده

BACKGROUND Massive hemorrhage during craniofacial surgery is common and often results in hypovolemia and hypotension. We conducted this study to assess the effect of the addition of routine central venous pressure (CVP) monitoring on the incidence of intraoperative hypotension and to evaluate the relationship between CVP and hypotension in this population. METHODS Data from our prospective craniofacial perioperative registry for children 6 to 24 months of age undergoing cranial vault reconstruction with CVP monitoring were compared with data from a historical cohort without CVP monitoring. The incidence and duration of hypotension in the 2 cohorts were compared. In the cohort of subjects with CVP monitoring who experienced hypotension, CVP at the onset of hypotension (T0) was compared with CVP 5 minutes before (T-5) and 5 minutes after (T+5) the onset of hypotension and with the baseline CVP. The amount of time spent at various CVP levels below the baseline, and the associated incidence of hypotension were also determined. RESULTS Data from 57 registry subjects were compared with data from 115 historical cohort subjects. The median total duration of hypotension in subjects experiencing hypotension was 278 seconds in the CVP cohort versus 165 seconds in the historical cohort; the median difference was 98 seconds (95% confidence interval [CI], -45 to 345 seconds). The incidence of hypotension was 18% in the CVP cohort versus 21% in the historical cohort; the difference in the incidence of hypotension was -3% (95% CI, -10% to 15%). Analysis using a linear mixed effects model showed a significant decrease in CVP from T-5 to T0 (95% CI, -0.9 to -2.2 mm Hg), a significant increase in CVP from T0 to T+5 (95% CI, 1.0-2.4 mm Hg), no significant difference in CVP between T-5 and T+5 (95% CI, -0.9 to 0.9 mm Hg), and a significant decrease in CVP from baseline to T0 (95% CI, -3.4 to -2.1 mm Hg). CVP at T0 was less than the baseline CVP in 97% of hypotensive episodes. When all cases were examined, CVP was ≥3 mm Hg below the baseline for 16% of the total time studied, with an associated incidence of hypotension of 2%. CONCLUSIONS The implementation of routine CVP monitoring was not associated with a decreased incidence and likely was not associated with a decreased duration of hypotension in this population experiencing massive hemorrhage. Hypotension was associated with a decrease in CVP, and resolution of hypotension was associated with an increase in CVP to prehypotensive levels. However, significant decreases in CVP below the baseline were common and usually not associated with hypotension. The routine use of CVP monitoring in these children is of questionable utility as a means to decrease the incidence and duration of hypotension.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of external and internal jugular venous pressures to monitor pulmonary artery pressure after superior cavopulmonary anastomosis.

The internal jugular vein continues to be the preferred site for cannulation to monitor central venous pressure despite the reported evidence of the accuracy of external jugular venous pressure (EJVP) to reliably predict internal jugular venous pressure (IJVP). Internal jugular venous cannulation carries a risk of thrombosis that can be life-threatening in children undergoing superior cavopulmo...

متن کامل

Determination of Central Venous Pressure from Intraocular Pressure

Background: In many clinical situations, knowledge of central venous pressure (CVP) is important.  Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery.  Those with carotid artery or jugular venous diseases as we...

متن کامل

Comparing the anatomy of the intrathoracic systemic central venous system in Iranian pediatrics and adults based on chest CT scan and evaluation of rate of catheter malposition in children

Background: Central venous catheterization is a procedure that is being performed frequently especially in critical clinical settings. In such conditions, good knowledge of the surface anatomy of venous structures is vital to avoid possible complications which could result in life-threatening situations such as bleeding and pneumothorax. Considering the difference between venous anatomy of chil...

متن کامل

Nasal reconstruction in surgery of the anterior skull base.

OBJECTIVES We sought to evaluate the effectiveness of a number of surgical maneuvers in nasal reconstruction of a diverse population of patients undergoing skull base surgery. Study design We conducted a retrospective review of a cohort of patients undergoing nasal reconstruction during surgery of the anterior skull base and craniovertebral junction. METHODS All patients undergoing skull base...

متن کامل

Measuring Symmetry in Children With Cleft Lip. Part 3: Quantifying Nasal Symmetry and Nasal Normalcy Before and After Unilateral Cleft Lip Repair.

OBJECTIVE   The purpose of this project was to develop objective computer-based methods to measure nasal asymmetry and abnormality in children undergoing treatment of unilateral cleft lip (UCL) and to determine the correlation of these measures to clinical expectations. PARTICIPANTS   Thirty infants with UCL undergoing cleft lip repair; 27 children with UCL aged 8 to 10 years who had previous...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 116 2  شماره 

صفحات  -

تاریخ انتشار 2013